background image

SP2400 – 4

FRONT PANEL FEATURES

INPUTS

 select buttons are used to choose the

program source for its respective zone. Only one
source may be selected at a time. These are non-
priority inputs. However, Input 4 can become a
Program Priority Input by setting the 

AMP

ADDRESS

 

 switch #7 UP. In this mode, when a

signal is present on Input 4, it automatically
overrides whatever input source is selected for that
zone. This is useful for jukeboxes or alternative
paging configurations.

INPUT OFF

 deselects Inputs 1-4 and activates

the 

MIC/LINE INPUT

 

.

MASTER VOLUME

 is used to adjust the overall

volume level for Inputs 1-4.

When 

OFF

 is selected, the Up/Down 

MASTER

VOLUME

 buttons adjust the output level for the

MIC/LINE INPUT

 

. The Master Volume setting for

Inputs 1-4 is retained in memory, and is recalled
when a program source is selected.

The 

Meter

 indicates the level at the 

PRE OUT

jack. Normally, it operates as a peak program meter
(PPM). When adjusting the 

MASTER VOLUME

level, the meter changes from level indication to
level setting indication. After five seconds, the
meters switch back to normal peak program
metering.

There are three 

STATUS

 indicators. The

OVERLOAD

 LEDs indicate when one of the

amplifiers is beginning to current limit. The 

ON

LED indicates when the SP2400 is operating.

The 

COMM PORT

 is used to connect to the

optional DSP card with a Palm™ Handheld or PC-
compatible laptop computer for configuration.

Turning the 

POWER

 switch on activates the soft-

start circuit in the power supply. The soft-start
circuit impedes in-rush current from the AC supply.

REAR PANEL FEATURES

PROGRAM INPUTS 1-4

 are stereo RCA

unbalanced inputs that accept line-level signals. The

LOCAL/REMOTE

 

 switches on the rear panel select

either the local program input signal connected here
or the program signal on the expansion bus. See
"Expansion In/Out" on page 18 for more information.

DIRECT OUTPUT

 is a buffered line-level output

providing the stereo signal from the program source
connected to 

INPUT 1

. Signal is always present at

the 

DIRECT OUTPUT

, regardless of whether 

INPUT 1

is selected as the source. This is useful for music-
on-hold and other external applications.

PAGING MIC

 is the connection for the paging

microphone. There are two connectors available: a
3-pin XLR and a 3-pin Phoenix-type connector. In
both cases, pin 1 is ground, pin 2 is signal high (+),
and pin 3 is signal low (–).

CONTROL

 is a Phoenix-type connector for

connecting external normally-open switches for
remote paging. Three options are available: page to
Zone A, page to Zone B, and page to the entire
system (

ALL CALL

). Connect the switches between

GROUND

 and the option of choice.

PHANTOM

 applies phantom power (+24VDC) to

pins 2 and 3 of the microphone input. Move both
switches to the down position to turn on phantom
power.

The 

GAIN +40 dB

 DIP switch is used to set the

gain for use with either a mic-level or a line-level
signal. Move both switches to the down position for
mic-level signals, and up for line-level signals.

The 

GAIN

 variable control is used to trim the mic

preamp gain for the best signal-to-noise ratio.

The 

LOW

 variable control is a shelving filter that

provides 12 dB of boost and cut below 100Hz.

The 

HIGH

 variable control is a shelving filter that

provides 12 dB of boost and cut above 12kHz.

The 

PAGING MIC VOX

 variable control adjusts

the ducking threshold for the paging mic. Rotate the
control clockwise to reduce the threshold. Rotate the
control counterclockwise to increase the threshold.

SP2400 MUSIC CONTROLLER

INPUTS

INPUTS

OFF

3
0
3
6
9

15
30
55

OFF

3
0
3
6
9

15
30
55

A

B

ON

OVERLOAD

STATUS

POWER

COMM PORT

ZONE A

MASTER

VOLUME

ZONE B

MASTER

VOLUME

1

2

3

4

1

2

3

4

Содержание Sound Palette SP2400

Страница 1: ...IN AMP ADDRESS ZONE B RS485 REMOTE AMBIENT MIC MIC VOX AMP IN PRE OUT HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN ZONE A AMP IN PRE OUT PAGING MIC...

Страница 2: ...sion cord receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un p...

Страница 3: ...d in U S A 2 INTRODUCTION The SP2400 is a microprocessor based dual channel music controller with two built in power amplifiers designed for use in a variety of installations requiring high performanc...

Страница 4: ...he local program input signal connected here or the program signal on the expansion bus See Expansion In Out on page 18 for more information DIRECT OUTPUT is a buffered line level output providing the...

Страница 5: ...signal source even numbered switches Move the switches up to select the local program source and down to select the remote external program source from the EXPANSION bus STEREO MONO switches configur...

Страница 6: ...MANUFACTURED BY MACKIE DESIGNS INC WOODINVILLE WA MADE IN USA FABRIQUE AU USA ZONE B OUTPUT 100 70V 8 STEREO RIGHT 1 2 3 4 1 2 3 4 5 6 7 8 MONO STEREO LOCAL 1 2 3 4 REMOTE 1 2 3 4 ZONE A OUTPUT 100 70...

Страница 7: ...Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSION OUT THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS I...

Страница 8: ...12 LOW GAIN AMP ADDRESS RS485 REMOTE AMBIENT MIC MIC VOX AMP IN PRE OUT HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXP...

Страница 9: ...30dB U M I C G A I N 0 60 30dB 30dB U M I C G A I N 0 60 30dB 30dB U PHANTOM POWER 48V DC 12 1 5V 11 G 1 G G G INPUTS OUTPUTS 100 240V 50 60Hz 1A MAX THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMA...

Страница 10: ...P ADDRESS switch 6 This allows the front panel buttons for both zones and all the remote controls to operate both zones simultaneously When an input is selected it is heard in both zones because Zone...

Страница 11: ...et to the down position as well 40 Note The Paging Mic has priority over the system including Input 4 5 Is there a manual switch for paging Up to three switches can be connected to the SP2400 PAGING M...

Страница 12: ...utput is configured for 8 ohm operation connect the speaker output directly to an 8 ohm load The amplifier will deliver up to 250 watts to each speaker If the amplifier is configured for either 70V or...

Страница 13: ...ttings Note There are several settings that can be changed inside the SP2400 These settings should be made prior to installing the SP2400 CAUTION These servicing instructions are for use by qualified...

Страница 14: ...the locations of the jumpers Note Each amplifier board must be configured separately On the Amplifier Boards J1 Jumper pins 1 and 2 for 8 ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2...

Страница 15: ...sis to allow proper ventilation If installing three or more SP2400s in a rack use a fan in the rack to move cool air in and warm air out of the rack s enclosure It may be necessary to provide a cool a...

Страница 16: ...e instruction manual which is the only way to fully understand how the SP2400 works However the Quick Start provides a quick overview so you can get the SP2400 set up and working right away Make sure...

Страница 17: ...ADDRESS switch 8 UP to enable the ambient mic See page 20 for more information on Using the Ambient Mic Expansion In Out If you are connecting two or more SP2400s in a system use the EXPANSION IN OUT...

Страница 18: ...operate both amplifiers In a zone configuration move the STEREO MONO switches down to combine the stereo signal into a mono signal for each program source Set the AMP ADDRESS switches to different add...

Страница 19: ...u let go of the switch the music begins to ramp up to its original volume Note 2 When the manual switch is off the voice activated VOX control for the paging mic is still operational Ensure that the P...

Страница 20: ...ibration Proce dure when used with Ambient Mic 1 Perform the Ambient Microphone Calibration Procedure described above 2 Switch the ambient mic OFF AMP ADDRESS switch 8 down 3 Adjust the MASTER VOLUME...

Страница 21: ...Speaker Connection If the SP2400 is not being used in a distributed speaker system you can reconfigure the amplifiers to drive an 8 ohm load Each amplifier can provide up to 250 watts into an 8 ohm lo...

Страница 22: ...connect the SP2400 to a computer loaded with the SPLinker software application The PC compatible computer must have an RS485 port to properly connect to the SP2400 It may be necessary to install an RS...

Страница 23: ...TO EXPANSION I O BUS ASSIGN TO EXPANSION I O BUS ASSIGN TO EXPANSION I O TO EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION...

Страница 24: ...position 30 dB 100V position Maximum Input Level 12 volts P P 15 dBu Rise Time 5 S Slew Rate 17 V S Preamplifier Section Input Levels Program Inputs 10 dBu to 10 dBu for maximum output level with inte...

Страница 25: ...y important Mackie Industrial is not responsible for any damage that occurs during shipping due to non conventional packaging Original packaging helps to minimize the possibility of shipping damage 3...

Страница 26: ...operation Press 3 on Power Up Paging Mic Level Adjustment Press and hold the Input 3 button while powering up the SP2400 Release the Input 3 button The lowest Paging Mic level is indicated on the LED...

Страница 27: ...3 R6 D1 F1 J3 J1 J4 J2 J8 J5 J11 J14 J9 J6 J10 J7 J13 J12 D2 JP1 R5 K1 R2 C2 4A SB 250V BROWN BLUE YELLOW YELLOW RED BLACK BLACK RED YELLOW YELLOW RED BLACK RED BLACK REMOVE JUMPER FOR 230V SP2400 230...

Страница 28: ...SP2400 Music Controller Mackie Industrial 16220 Wood Red Rd NE Woodinville WA 98072 USA 888 337 7404 Outside the U S 425 487 4333 Fax 425 487 4337 www mackieindustrial com...

Отзывы: