background image

1.1.10. Delay before play - DLY 

This command configures the delay before first play value. This setting only 
effects start triggers generated on Connector 1. 
 
Syntax; 
DLY

value

 

 
Where; 

value 

= (+) 1 thru 99 for seconds,  (-) 1 thru 99 for minutes. (default = 0) 

 
Example; 
DLY+5<CR> configures delay before first play for 5 seconds. 
 

1.1.11. Command listing- LST 

This command lists the commands available to control the MacFi-se . 
 
Syntax; 
LST 
 
Example; 
LST<CR> displays a list of commands, values and descriptions. 
 

1.1.12. Pause between play repeats - PAS 

This command configures the pause between play repeats value. 

NOTE - This 

setting only effects start triggers generated on Connector 1. The 
configuration of this value overrides the default setting of configuration 
switches 3 and 4 ON, 30 second delay between plays. This is helpful as 
the unit may be configured with a custom time via RS-232, but used in the 
start input remote control mode. 

 
Syntax; 
PAS

value

 

 
Where; 

value 

= (+) 1 thru 99 for seconds,  (-) 1 thru 99 for minutes of pause between 

repeats. (default = 0) 

 
Example; 
PAS-30<CR> configures pause between play repeats to be 30 minutes. 

 

1.1.13. Number of Plays per trigger - PLS 

This command configures the number of times a message will play per trigger. 

NOTE - This setting only effects start triggers generated on Connector 1. 
The configuration of this value overrides the default setting of 
configuration switches 1 and 2 ON, play message 4 times. 

 
Syntax; 
PLS

value

 

 
Where; 

value

 = 1 - 99 repeats. (default = 1) 

 
Example; 
PLS20<CR> configures message to play 20 times per trigger. 

1.1.14. Play Message - PLY 

This command is to playback messages which have been recorded into the 
MacFi-se . 
 
Syntax; 
PLY

msgnumber, repeat,pause

 

 
Where; 

msgnumber

 = the message location to be played<1-99>, multiple messages 

may be played in sequence by placing  them in quotes, ie "1,2": The 
messages are played like a single message bound by the repeat and pause 
specified. Up to eight messages are supported in this mode.

 

repeat 

= the number of times to play the message<1-99> 

pause

 = time to pause between repeats 1 - 99 seconds (+) or 1 - 99 minutes (-) 

 
Example; 
PLY6,10,+5<CR> will play message six, ten times with a five second pause 

between the repeats. 

 
If no message number is given, the system will play the next available message 
in memory. This defaults to message # 1 at power up. If no repeat is given, the 
system will play the message one time. If no pause is given, the system delays 
one second between subsequent message plays. 
 
Repeat may not be entered without message number being entered. Pause may 
not be entered without repeat being entered. 

NOTE: Multiple PLY commands 

may be issued to the unit while it is playing. In this case the MacFi-se will 
queue the messages and play them in the order they are received. The 
STP command will stop playback and clear the queue. 
 

1.1.15. Set Message Enable - PRI 

Messages can be enabled or disabled using this command. Normal conditions 
will warrant each message to have a "1" priority meaning they are active. If a 
message is set for "0", then it is considered inactive and will not be played in the 
sequential mode or when a PLY command is issued relating to that message 
number. 
 
Syntax; 
PRl

msgnumber,status

 

Where; 

msgnumber = 

the message location<1-99> 

status is the priority, E for enable, D for disable. 
 
Example; 
PRI5,D<CR> will establish message five as inactive. 
 
Each message will default with a priority of "E" or enabled after it is recorded. 
Disabled messages are displayed with a "D" in front of the message number 
when the message directory is listed. Disabled messages cannot be played until 
they are enabled. 

 

 

Отзывы: