M2 User's Manual V 1.0 Revised 4/21/2003
Page 12
2.4.3. CH 2, Relay:
Playing relay is a Form C contact closure. This contact is activated for the length of the
playing message and is released when the message ends or is stopped. The playing relay
is capable of handling 1A at 24VDC or 0.25A at 110VAC, non-inductive load.
N
o
rm
a
lly
Open
C
o
mmo
n
N
o
rm
a
lly
Cl
os
ed
2.4.4. CH 2, Remote Control:
12 position pluggable terminal strip. Use for remote control start of
message playback and stopping messages.
Stop
Connect to common to stop message playback
Start 1
Connect to common for message 1 playback
Start 2
Connect to common for message 2 playback
Start 3
Connect to common for message 3 playback
Start 4
Connect to common for message 4 playback
Start 5
Connect to common for message 5 playback
Start 6
Connect to common for message 6 playback
Start 7
Connect to common for message 7 playback
Start 8
Connect to common for message 8 playback
Start 9
Connect to common for message 9 playback
Start 10
Connect to common for message 10 playback
Com
Connecting any input to common activates the function
2.4.5. CH 2, Playing LED
Green LED which indicates the playing and boot status of the M2.
Off
M2 is not playing or no power supplied to the unit
On
M2 is playing
Blink
M2 is executing boot procedure