Delivery, internal transport, unpacking
Version 1.0.2 dated 2018-09-12
Page 75
Translation of the original instructions
DH55G
GB
DH
55
G_
G
B
_
3.f
m
OPTIMUM
M A S C H I N E N - G E R M A N Y
®
3.5.1
Foundation and ground
Check the ground. The ground must bear the load.
The ground must be prepared in a way that potential coolants cannot penetrate the floor.
3.6
Fixing
In order to provide for the necessary stability of the geared drill,
it is necessary to firmly connect the geared drill with its foot to the ground. We recommend the
use of anchor rods DIN 529 M16 x 200
Fix the foot of the geared drill to the ground with the holes pre-drilled for this purpose.
ATTENTION!
Tighten the fixing screws of the geared drill only as much that it is safely fixed and
cannot break away or tilt over.
If the fixing screws are too tight in particular in connection with an uneven substructure it may
result in a broken stand of the machine.
200
M16