5
OPERATION MANUAL
21. CHECK DAMAGED PARTS. Before using the tool, check guards or other parts to see if they
are damaged. If damaged carefully check to determine that the tool will operate
properly and perform its intended function. Check for alignment of parts, moving
parts are not binding, parts are not broken and correctly mounted, or any other condition
that may affect the tools operation. Any guard or other part that is damaged should be
properly repaired or replaced
22. DIRECTION OF FEED. Feed work into a blade or cutter against the direction of rotation of
the blade or cutter.
23. NEVER LEAVE TOOL RUNNING UNATTENDED. TURN POWER OFF. Do not leave the tool
until it has come to a complete stop. If fitted, lock the main switch in the OFF position,
remove the switch key from the switch. Place the key in a location that is inaccessible to
children and others not qualified to use the tool.
SAFETY RULES Cont.
q
Wear eye protection.
q
Do not remove offcuts that have been jammed until blade has stopped.
q
Maintain proper adjustment of blade tension, blade guides, and thrust bearing.
q
Adjust upper guide to just clear workpiece.
q
Hold workpiece firmly against table
MATERIAL TO BE CUT
The machinel is intended to cut material such as steel. Iron, copper, etc.
Never use this tool
to cut wood and explosive metal material.
USE A CORRECT PLUG
Different countries use different plugs. The correct approved plug must be installed by a
qualified electrician.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding provides a path of least resistance for
the electric current reducing the risk of electric shock. This tool is equipped with an electric
cord that has an equipment-grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and grounded in accordance with all
local codes and ordinances.
Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed
by a qualified electrician. Improper connection of the equipment-grounding conductor can
result in the risk of electric shock. The grounding wire must have an insulation that has an
outer surface that is green, with or without yellow stripes. If the cord is repaired or replaced or
the plug needs replacing, a qualified electrician must be used to make the change.
Page 6
Instructions Manual for BS-5V (B004)
06/07/2017
Содержание BS-5V
Страница 11: ...10 OPERATION MANUAL WIRING DIAGRAM Page 11 Instructions Manual for BS 5V B004 06 07 2017...
Страница 12: ...11 OPERATION MANUAL SPARE PARTS Page 12 Instructions Manual for BS 5V B004 06 07 2017...
Страница 13: ...12 OPERATION MANUAL SPARE PARTS Cont Page 13 Instructions Manual for BS 5V B004 06 07 2017...
Страница 14: ...13 OPERATION MANUAL Page 14 Instructions Manual for BS 5V B004 06 07 2017...