4.2 Set date and time 

 
To set the time and date of the Network Adapter, switch to the 

System

 panel on the left side. Choose the entry 

System

. Click 

on 

Sync with Browser

. Save the settings by pressing 

Save & Apply

 

 

Pic.5: Setting date and time  

 

The time zone is set to Europe/Berlin by default. The time zone can be changed by choosing a new time zone from the drop 
down panel 

Timezone

 

NOTICE

 

The clock date and time can also be synchronized with an internal time server. Configure register 

Time 

Synchronization

. Please be aware that the time synchronization is only possible after the full installation 

and setup of the Network Adapter.  

 
Press 

Save & Apply

 to save the changes.  

 

NOTICE

 

The language settings are automatically adopted from the connected computer. However, they can be 
changed to DE or EN on the 

Language and Style

 tab of the 

System

 menu item (Fig. 5). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 162735

Страница 1: ...VIS II Content 1 Introduction 2 2 Connection setup 2 3 Installation of the Network Adapter 3 4 Configuration of the Network Adapter settings 4 5 Configuration of the WiFi module 12 6 Configuration of...

Страница 2: ...is connected via an ethernet cable CAT 5E to the Network Adapter The Network Adapter is connected via an ethernet cable CAT 5E to the network Switch Router PC Server The following scheme shows the fin...

Страница 3: ...riod take it out of operation and disconnect it from the power supply Connect the Network Adapter to the power supply via the connector as indicated in pic 1 The device will start up and can now be co...

Страница 4: ...ngs connect the instrument directly or via a switch to a configuration PC with an Ethernet cable CAT5E For the connection use interface eth1 see Pic 2 Pic 2 Ethernet interfaces NOTICE The availability...

Страница 5: ...actory reset NOTICE Please note that in case of serious problems or incorrect settings during the setup of the network module there is always the possibility of a factory reset and starting the proces...

Страница 6: ...sing a new time zone from the drop down panel Timezone NOTICE The clock date and time can also be synchronized with an internal time server Configure register Time Synchronization Please be aware that...

Страница 7: ...3 Interface settings overview To perform or check the interface settings switch to the Network Interfaces panel on the left side and see the following over view Pic 5 Pic 5 Network Adapter interface o...

Страница 8: ...on of IP LAN0 choose EDIT LAN0 If necessary change the IP address and netmask to your company s network IP address for the gateway LAN0 eth0 as shown in the following Pic 6 Save the settings by pressi...

Страница 9: ...rk Adapter LAN0 eth0 as shown in the following Pic 7 Confirm the question Really switch protocol by clicking on Save the settings by pressing Save and in the next window by pressing Save Apply Pic 7 N...

Страница 10: ...meters nounix noserverino Pic 9 Network Mount Settings NOTICE In case of domain networks the username needs to be entered as follows username domain NOTICE To avoid mistakes during entering the passwo...

Страница 11: ...tab Advanced settings in the field Use custom DNS servers see Pic 11 Save the settings by pressing Save and in the next window by pressing Save Apply Pic 10 Network Adapter static IP LAN0 DNS General...

Страница 12: ...Wireless in the section Network Choose EDIT for the demo_ssid and configure the WiFi module Pic 12 NOTICE Please note that WiFi antennas are not included Pic 12 Wireless overview Enter the SSID of the...

Страница 13: ...s in the next window by pressing SAVE APPLY The configured WiFi client appears in the list of Associated Stations and in the Wireless Overview Pic 15 as well as in the Interfaces Pic 5 Pic 14 Wireless...

Страница 14: ...allation steps in chapter 4 before starting the photometer configu ration A successful connection to the mount should be given before you proceed with this chap ter 6 1 Network configuration Connect t...

Страница 15: ...Password none Pic 18 Data export settings NANOCOLOR spectrophotometer Before pressing OK connect the spectrophotometer to the Network Adapter with help of a LAN cable CAT 5E The spectrophotometer will...

Страница 16: ...filled with the following credentials Username root Password mclh When using the ACRON connection in the spectrophotometer the settings for the ACRON folder path must be set to mclh smb1 see Pic 19 To...

Страница 17: ...etwork module Check user Data Check password Check accessibility of the shared folder by ping Check and change the SMB version Network Adapter error codes Error Meaning IDS_NET_UNKNOWN_ERROR Unknown N...

Страница 18: ...ght mouse button on the folder e g Test Network which you would like to share Select Properties Pic 20 Share folder Properties Open the register Sharing see pic 21 and select Share Pic 21 Folder share...

Страница 19: ...lder is confirmed in a new dialogue see Pic 22 Close the window by confirming with Done Pic 22 File Sharing Click on Advanced Sharing Pic 23 Folder Properties Advance Sharing Servername Test network S...

Страница 20: ...Sharing Enter the user to the text field which should be added e g user Pic 25 User selection Click on Check Names see Pic 25 Choose the user from the list and set the correct permissions for the user...

Страница 21: ...Pic 28 Folder sharing Click Close The network drive is now successfully shared 9 Contact If you have further questions please do not hesitate to contact us Technical support and customer service Tel...

Отзывы: