215276
17
Revision A
1033003
D
B
A
J
H
J
L
F
E
K
C
C
J
G
Figure 3.23: Power Limiter Harness (MD #256651) Installation
4.
Connect the power limiter harness (MD #256651) as follows:
•
Connect 4-pin male connector (A) to piston pump (B).
•
Connect 4-pin female connector (C) to header pump relay harness (D).
•
Route power wire with terminal (F) through frame channel hole (E) and connect to bus bar stud (G) beside battery.
Tighten terminal nut to 11 Nm (100 lbf·in).
•
Secure harness to chassis harness (H) using cable ties (J) (MD #21763). Locations of module (K) and fuse (L) are
approximate.