214603
395
Revision A
open at the relief setting. Otherwise, reduce the ground speed to maintain the correct system load and header drive
operation.
The overload pressure is programmed into the CDM when inputting the header parameters. Refer to
Display Module (CDM) Configuration, page 90
and Table
for suggested settings.
If lift and drive capacity problems develop, the pressure relief valve may require adjusting. Contact your
MacDon Dealer.
Table 5.3 Relief Valve and Overload Settings
Header Model
Application/System
Windrower Differential Relief
Setting
(Header Attached)
kPa (psi)
Suggested Overload Warning
Setting
kPa (psi)
R80 and R85
Disc Pressure
37,921 (5500)
37,232 (5400)
D60, D65, and
A40D
Reel/Draper Pressure
19,995 (2900)
19,995 (2900)
Knife/Conditioner
Pressure
27,579 (4000)
27,579 (4000)
Flow Control Blocks
1005510
Figure 5.197: Draper Header Hydraulics
Two hydraulic valve blocks with multiple cartridges are used
for the various windrower functions and are controlled by
the windrower control module (WCM) according to the
inputs from the Operator. The valve blocks are located
behind the left cab-forward side platform.
The valve blocks do not require any scheduled
maintenance other than to check for leaking fittings or loose
electrical connections. If service is required, contact your
MacDon Dealer.
1005509
Figure 5.198: Rotary Disc Header Hydraulics
Содержание M205
Страница 3: ...Declaration of Conformity 1025029 ...
Страница 4: ...1025030 ...
Страница 20: ......
Страница 36: ...214603 16 Revision A Figure 1 23 Safety Signs Right Cab Forward Side 1011020 A B C D E F G H J K L M SAFETY ...
Страница 401: ...214603 381 Revision A Fuse Box Decal Figure 5 175 Fuse Decal 1022431 MAINTENANCE AND SERVICING ...
Страница 440: ......
Страница 462: ......
Страница 511: ...windshield wipers 56 INDEX ...
Страница 512: ......