MAINTENANCE/SERVICE
Form 169469/169470/169471
145
Revision C
s. Position end cap (F) onto filter housing with
aspirator pointing approximately down.
t. Align arrow (H) to unlock position on end cap
and push end cap fully onto housing.
u. Rotate end cap clockwise until catch (G)
engages housing to prevent end cap from
turning.
v. Close engine compartment hood.
7.8.5.2 Charge Air Cooling
After the intake air passes through the air filter, it
passes through the turbocharger (J) which
boosts the pressure. This process heats the air
so it is passed through pipe (K) to a cooler
before entering the engine intake. The cooler is
located in the cooling box (L) behind the radiator
and should be cleaned daily with compressed
air. Refer to Section 7.9.3, Cooling Box
Maintenance.
G
H
F
J
K
L