214735
108
Revision A
4.7
Calibrating the Windrower and Header
When a header is attached to the windrower, the Harvest Performance Tracker (HPT) will recognize the header ID
and determine the appropriate systems to calibrate. The following sensors may require calibration depending on
header type:
•
Header height
•
Header angle
•
Header float left
•
Header float right
•
Reel height
•
Reel fore-aft
•
Swath compressor
Recalibration is required if the HPT is replaced, a position sensor is replaced, sensor readouts are erratic, or the
first time a certain header type and attachment are connected to the windrower.
NOTE:
To calibrate the knife drive, the header must be attached and engaged. If the header is disengaged when
calibration is selected, the message ENGAGE HEADER will appear on the screen.
CAUTION
Before starting the machine, check to be sure all bystanders have cleared the area.
1016140
A
B
C
Figure 4.138: Opening the Main Menu
1.
Start the engine, and engage the header.
2.
Press soft key 5 (A) to open the main menu.
3.
To scroll to the settings icon (C), use the HPT scroll
knob (B) or the ground speed lever (GSL) scroll wheel
(not shown).
4.
Press the HPT scroll knob (B) or the GSL SELECT
button (not shown) to activate the settings menu
options.