214685
282
Revision A
Figure 7.286: John Deere S7 Display
–
Height
Sensing Error Message
12. Read error message and then press OK.
13. Proceed to
Checking Voltage Range from the Combine
Cab (John Deere S7 Series), page 282
Checking Voltage Range from the Combine Cab (John Deere S7 Series)
The auto header height sensor output must be within a specific range, or the feature will not work properly.
Combine
Low Voltage Limit
High Voltage Limit
Minimum Range
John Deere S7 Series
0.5 V
4.5 V
3.0 V
Check the sensor
’
s output voltage range from combine cab according to instructions that follow.
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
1.
Position header 150 mm (6 in.) above ground, and unlock float.
Содержание FlexDraper FD1 Series