215184
190
Revision A
6.2.6
Converting from Ultra Narrow or Narrow Configuration to Wide or Ultra Wide
Configuration
One flighting kit (MD #287031) is required to convert to this configuration. Two flighting plugs (MD #213084), two M6 hex
head bolts (MD #252703), and two M6 tee nuts (MD #197263) are recommended to close the flighting mounting locations.
These parts can be ordered from a MacDon Dealer.
1032279
1
2
A
A
A
A
3
4
A
A
A
A
Figure 6.34: Auger Configurations
–
Rear View
1 - Narrow Configuration
2 - Ultra Narrow Configuration
3 - Wide Configuration
2 - Ultra Wide Configuration
The Narrow, Ultra Narrow, Wide, and Ultra Wide auger
configurations are shown at right. When converting from
Narrow or Ultra Narrow configuration to Wide configuration,
you will need to replace existing bolt-on flightings (A). When
converting from Narrow or Ultra Narrow configuration to
Ultra Wide configuration, you will be removing all bolt-on
flighting.
NOTE:
Some parts have been removed from the illustrations for clarity.
1.
Improve access and ease installation by removing the float module from the combine. For instructions, refer to the
header operator
’
s manual or technical manual.
1032283
B
D
A
C
Figure 6.35: Narrow Configuration
–
Right Side
2.
Remove bolts (A) and access cover (B) from the right side of
the auger. Retain for reassembly.
3.
Remove hardware (C) and bolt-on flighting (D) from the
right side of the auger. If converting to the Wide
configuration, discard the removed flighting, but retain
hardware to attach the new flighting. If converting to the
Ultra Wide configuration, the hardware may be discarded
as well.
NOTE:
If converting to Ultra Wide configuration, hardware may be
discarded as well.
4.
Repeat Step
and Step
for the
remaining bolt-on flighting(s) according to whether you are
converting to Wide or Ultra Wide configuration.