background image

MANUAL

DT-2100

52

Back

1

2

3

4

5 6

7

8

9

10

11

12

1.

Mains voltage 180–260VAC

2. Balanced audio output, right (XLR)
3. Balanced audio output, left (XLR)
4. Alarm contact jack
5. Aux. COM2-port

*

6. Data COM1 for upgrading software (PC).
7 . Audio jack right/left (RCA)
8. SVHS jack
9. Video out (1+2)
10. Transport current output Parallel LVDS
11. LNB in 13/18V DC, 350mA, 22kHz
12. IF out

*

 Used for future functions (optional)

00983-4 DT-2100 ENG-1.p65

2001-03-29, 11:20

52

Содержание DT-2100

Страница 1: ...QPSK DT 2100 ENGLISH 49 64 MANUAL ENG 1 010326 00983 00983 4 DT 2100 ENG 1 p65 2001 03 29 11 20 49 ...

Страница 2: ...g net automatically A future advantage is an upgradeablesoftwarepackage ItiseasytodownloadnewfunctionsincomingfromsatelliteoraPC In order to increase reliability all components have been selected with the greatest attention and each unit is individually tested before delivery Important Digital signals put great demands on the installation s LNB Older microwave heads often exhibit an unsatisfactory...

Страница 3: ...erface 3 Fan 4 Card reader 5 Display 6 LED Alarm red QPSK lock yellow On indication green 7 Button Left Right Up Down 8 Button Menu Enter 2 4 5 6 7 8 3 1 The fan is temperature regulated and starts at 30 35 00983 4 DT 2100 ENG 1 p65 2001 03 29 11 20 51 ...

Страница 4: ...ed audio output left XLR 4 Alarm contact jack 5 Aux COM2 port 6 Data COM1 for upgrading software PC 7 Audio jack right left RCA 8 SVHS jack 9 Video out 1 2 10 Transport current output Parallel LVDS 11 LNB in 13 18V DC 350mA 22kHz 12 IF out Used for future functions optional 00983 4 DT 2100 ENG 1 p65 2001 03 29 11 20 52 ...

Страница 5: ...de of the module is marked and this side should face the marking for the DVB CI socket on the DT 2100 CARD READER The right card reader is used for a downloaded embedded coding system i e Conax and Viaccess The card should be inserted with the gold coloured contact surface turned downwards inwards Iftheprogrammecardisnotupdated thefollowingmessagewillappearontheTVscreen Nosubscription Important Wh...

Страница 6: ...nge the channel Right use this button to select numbers To select options on the Info menu Down use this button to select settings on menus MENU use this button to activate the menu De activate the Info menu ENTER save and move to the next menu option Please refer to the menu tree on page 55 SELF TEST One of the features of the DT 2100 is the self test When it s started various parts will be teste...

Страница 7: ...his button to activate the menu De activate the Info menu ENTER save and move to the next menu option Menu overview For Info press Right button Once Twice 3 times 4 times 5 times Programming Press Menu button Select IF frequency Select polarization Select 22kHz Select symbol rate Select FEC Select language audio Select language subtitles VPID video PID APID audio PID PCRPID program clock reference...

Страница 8: ...requency L O on the microwave head LNB The frequency of the satellite channel L O frequency LNB Intermediate frequency IF which is to be set Example A satellite channel with frequency 11 309 and LNB of L O 9 750 MF 11 309 9 750 1559 is the frequency to be set POLARIZATION UsetheUp DownbuttonsforselectingthedesiredpolarityH V ENTER Press the Enter button to save and jump to the next menu selection ...

Страница 9: ...or automatic searching of FEC ENTER Press the Enter button to save and move on to the next menu option LANGUAGE sound Use the Up Down buttons to select the required language ENTER Press the Enter button to save and move on to the next menu option LANGUAGE subtitles Use the Up Down buttons to select the required language ENTER Press the Enter button to save the setup Programming ENTER SOUND LANGUAG...

Страница 10: ...tosetthePID see page 61 Use the Up Down buttons to select a required channel ENTER Press the Enter button and after a few seconds the channel will be displayed on theTV screen Important PIDs are only to be used when you have problems finding a required channel CHANGING CHANNEL Switching to another channel within the transponder is simply done by using the buttons and the display on the front panel...

Страница 11: ...signal quality is inadequate 04 Operating limit for sound and pictures Press the Right button to move to the next step on the menu Information BER GOOD EB NO 10DB BER XX 05 EB NO 8 0DB BER GOOD EB NO 10DB BER XX 05 EB NO 8 0DB EB NO Gives information about the quality of the received signal It s displayed together with the BER value and Wait is displayed until the value is calculated 7 Inadequate ...

Страница 12: ...ng the Up Down buttons ENTER Press the Enter button again Press the Right button to move to the next step on the menu Information VIEW LOG 1 ENTRIES CLEAR LOG 1 ENTRIES CLEAR ERROR LOG YES CARD INFORMATION CI When card information is activated a menu will be displayed on theTV screen Fromthismenu severaloptionscanbeselected Theappearanceof the menu will differ depending on which coding system is b...

Страница 13: ...ess the Menu button Then press the Enter button until the ENTER StartTrans Scan menu appears SelectNOforPID setting See page 58 Use the Left Right and Up Down buttons to set the required PID ENTER PresstheEnterbuttontostartthechannelsearch VPID video PID APID audio PID PCRPID program clock reference TextPID text TV PID AUDIO LEVEL CURRENT 15 AUDIO LEVEL It s possible to change the audio level with...

Страница 14: ...stem B AUDIO OUTPUT 1 Balanced 600Ω audio pair XLR 1 Unbalanced 600Ω audio pair RCA Frequency response 20Hz to 20kHz 0 5dB THD 65dB GENERAL DATA Alarm Active high low logic outputs on rear panel TS output Parallel LVDS output Input voltage 180 to 260 VAC 50 60Hz Cooling fan Built in Units may be stacked Width 19 rack Height 1 rack unit 1HE Temperature 10 to 45 Working 20 to 70 Storage 002 03 XXXXX...

Страница 15: ...L 12 25 SYNC 13 GND SVHS Y C 1 Y 2 C GND Audio unbalanced RCA contact female Video 1 2 BNC contact female LNB IN F contact female LNB OUT F contact female Right Left 9 pin D sub male 9 pin D sub hane 4 pin SVHS contact mini DIN female 25 pin D sub female 1 2 3 1 2 3 9 1 25 1 9 1 Alarm When alarm occurs A 0V B 3 3V Max 15mA A B ALARM CONTACT Pin A B Alarm 0 1 Operation 1 0 Center pin GND 0 0 volt 1...

Страница 16: ...Art nr 9270045 macab ab publ vannhögsgatan 7 se 231 66 trelleborg tel 0410 36 36 00 fax 0410 36 36 01 e post info macab se www macab com 00983 4 DT 2100 ENG 1 p65 2001 03 29 11 20 64 ...