User Guide HC - Copyright © 2008 MAC3. All right reserved.
Man 01 Disegno 6328
36
Via Baldanzese, 149 50041 Calenzano FI
Tel. 055 8877672 – Fax 8877068
www.mac3.it - e-mail: [email protected]
English
No water........
Lack of water found
Electro-pump off
Automatic and programmable
reset
(Set at the factory for 5 resetting
attempts every 5 min. if
unsuccessful the reset operation
will be attempted every 50
minutes for 24 times. After which
the system will remain in
permanently blocked state)
Off
Check that water is
present.
Restore correct power
priming condition
Check that the filter is not
clogged
Disconnect the power
supply
Wait for the display to
switch off
Restore the power supply
PrsSensor Fault.
A pressure sensor fault has been
found
Off
Consult the assistance
service.
Imax fault
An excessive amount of electrical
current is registered in the pump
Off
Verify that the pump is
used in the conditions
suggested by the
manufacturer
Make sure that there are
no points of friction or
blocking with regard to the
rotor.
Do the setting sequence to
set the MaxCurr
parameter.
5.2.
Breakdown Search
In case of damage please the message table (paragraph 5,1) – what to do.
In any of this information is suitable for solving the problem please contact the assistance service (Ph.
+39.0558877672) giving the following information:
Product version
N° series of the product
6.
W
ARRANTY
Attached to the product is provide the warranty documents with all conditions.
7.
M
AINTENANCE
M
ENU
During usual operation it is available a
Maintenance
Menu that displays some parameters to
check the functioning of Hydrocontroller.
To enter this menu keep pressed for 3 seconds the key
+
.
It will be displayed:
Keeping the key
-->
the display will show the parameters of
Maintenance
Menu in right
way.
To display in left way you must keep pressed altogether the keys
and
ENTER
.
Language
English