Model LFMR6
Installation, Operation, and Maintenance
File: LFMR6-IOM.doc
8
Rev:
2/22/08
MAINTENANCE
NOTE:
To avoid personal injury, permit only qualified personnel to perform maintenance on this lift.
See repair parts breakdown for replacement parts.
ALWAYS:
Keep all bolts tight. Check periodically.
ALWAYS:
Keep lift clean. Raise lift when cleaning floor area.
DAILY:
Check lock bar handle and release mechanism for damage or binding.
WEEKLY:
Inspect all lift parts for signs of damage due to improper use.
MONTHLY:
Lubricate lock bar pivot bolt and lock bar handle pivot points.
MONTHLY:
Lubricate all hinge joints if there are signs of rusting.
SEMI-ANNUALLY:
Check fluid level of lift power unit and refill if required. Use only Dexron III ATF or 10wt
anti-foam, anti-rust hydraulic oil. If fluid is required, inspect hose and connections and cylinder seals. Repair
as required.