OM-210 089 Page 14
3-5.
Selecting A Location And Connecting Input Power For 120 VAC Model
1
Rating Label
2
Grounded Receptacle
A 120 volt, 20 ampere individual
branch circuit protected by time-
delay fuses or circuit breaker is
required.
3
Plug From Unit
Select extension cord of 14 AWG
for up to 50 ft (15 m) or 12 AWG for
50 up to 200 ft (61 m).
Y
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
2
1
3
18 in
(460 mm)
18 in
(460 mm)
ST-802 178