background image

Instruction Manual

MAN-045

2

www.macmedical.com

KEEP THIS MANUAL

DESCRIPTION OF PRODUCT

The products covered in this manual are: 
all Stainless Steel IV Stands.

PURPOSE OF THIS MANUAL

This manual covers Stainless Steel IV 
Stand assembly, use, cleaning and 
maintenance.

Table of Contents

Standard Features

   

3

Unpacking and Inspection Instructions

   

3

Assembly Instructions (IVS-5000, IVS-6000, IVS-7000 Series Stands)

   

4

Adjusting the Height of the Foot Operated IV Stand (IVS-3000/IVS-4000 Series)

   

7

Adjusting the Height of the Hand Operated IV Stand (IVS-5000/IVS-6000/IVS-7000 Series)

   

8

Intended Use - Casters and Wheels (Care and Maintenance)

   

9

Cleaning and Maintenance

   

10

Replacement Parts - General

   

11

Limited Lifetime Warranty

   

12

Содержание IVS-3002

Страница 1: ...CTION MANUAL Read and understand all of the instructions and safety information in this manual before operating this product MAN 045 REV B 06 2021 2021 MAC Medical Inc IV STANDS Assembly Usage and Maintenance ...

Страница 2: ...tenance Table of Contents Standard Features 3 Unpacking and Inspection Instructions 3 Assembly Instructions IVS 5000 IVS 6000 IVS 7000 Series Stands 4 Adjusting the Height of the Foot Operated IV Stand IVS 3000 IVS 4000 Series 7 Adjusting the Height of the Hand Operated IV Stand IVS 5000 IVS 6000 IVS 7000 Series 8 Intended Use Casters and Wheels Care and Maintenance 9 Cleaning and Maintenance 10 R...

Страница 3: ...ent 68 108 2 Swivel Casters Unpacking and Inspection Instructions CAUTION The IV Stand is heavy and it is recommended that at least two people assist in the unpacking If the shipping container appears to be damaged in any way contact the shipping company immediately Save all damaged packaging materials Carefully inspect the IV Stand while unpacking If any damaged or defective parts are seen call y...

Страница 4: ...TION If any components of the IV stand are damaged or missing contact your MAC Medical representative immediately Do not use substitute parts Failure to use the proper replacement parts could lead to personal injury and damage to the IV Stand 1 Remove all loose packaging from the shipping container 2 Remove all IV Stand components from the shipping container 3 Inspect IV Stand components to ensure...

Страница 5: ... in the center of the Wheeled Base from the bottom so that the threads of the bolt protrude through the top of the Wheeled Base Position the bottom of the Lower IV pole over the bolt where it protrudes from the Wheeled Base Fig 4 Using the 5 8 Socket Wrench tighten the bolt onto the Lower IV Pole using a rightward clockwise twist Make sure the bolt is tightened securely Fig 5 Bolt Fig 2 Unscrew Bo...

Страница 6: ...truction Manual MAN 045 6 www macmedical com WARNING Make sure that the IV Stand is assembled as described before use Fig 6 Fully Assembled Stand The IV Stand is now fully assembled and ready for use Fig 6 ...

Страница 7: ...etween 68 and 108 Lowering To lower the height of the Foot Operated IV Stand grasp the Upper IV Pole with one hand and press down on the Foot Release button Lower the Stand to the desired height then let up on the Foot Release button Figs 8 9 IMPORTANT Make sure to have a firm grip on the Upper IV Pole when activating the Foot Release or the Upper IV Pole will slam down Fig 7 LiftuponUpperIVPole F...

Страница 8: ...sted to any height between 68 and 108 Lowering To Lower the height of the Hand Operated IV Stand grasp the Upper IV pole with one hand and turn the Knob Left Counterclockwise with the other to loosen it Lower the Stand to the desired height When the stand is at the desired height turn the knob Right Clockwise to tighten it Fig 12 IMPORTANT Make sure to hold the upper IV pole when lowering it or th...

Страница 9: ...e bolt nut should be removed and the foreign material removed If the internal components are intact the caster can be reassembled Rubber tires can be badly worn and cause erratic steering bumping load shifting and floor damage Replacement wheels and casters should be kept on hand to keep equipment in working order Intended Use IV or intravenous poles are devices used to hold bags of fluid or medic...

Страница 10: ...d water Bleach or any products containing Chlorine Hydrochloric Acid Denatured Alcohol NOTE Always follow the manufacturer s directions for any chemicals used on the stainless steel surfaces of the IV Stands Use the following cleaning materials and agents Soft clean lint free cloth Distilled water Distilled water with mild detergent Cleaners approved for use on stainless steel How to Clean a Stain...

Страница 11: ...d parts and authorized services contact your MAC Medical representative Item ID Part Number Description QTY Model 1 IV0010 03 WM IV 2 Hook 1 IVS 3002 IVS 4002 IVS 5002 IVS 6002 IVS 7002 1 IV0010 05 IV 4 Hook 1 IVS 3004 IVS 4004 IVS 5004 IVS 6004 IVS 7004 1 IV0018 02 IV 6 Hook 1 IVS 3006 IVS 4006 IVS 5006 IVS 6006 IVS 7006 2 ST0098 IV Pole Knob 1 IVS 5000 Series IVS 6000 Series IVS 7000 Series 3 T0...

Страница 12: ...he factory It is the customer s responsibility to inspect the product for packaging damage before signing the BOL This warranty does not apply to products which have been subject to abuse misuse accident modification alteration tampering negligence lack of routine maintenance or misapplication or products that have been repaired by other than MAC Medical or its authorized representatives This warr...

Отзывы: