9
Temperature adjusts at scale of 10
℃.
The Flasher 4.2 will keep flashing before output temperature reaches the setting temperature.
- Adjust air flow by clicking the Buttons
⑨
,
⑩.
Turn ON/OFF Switch to I, the temperature is fixed at 50
℃
for cooling down.
8.3
Preset mode selection
4 preset modes are available for quick slection of temperature and airflow setting for most
frequent and defined applications.
Turn on the tool. Click the button the Mode Selection Button
⑥
to select one desired mode of
preset temperature and air flow.
8.4
Preset mode input
Select one preset mode according (
see
8.3
)
Set desired temperature and airflow by clicking buttons
⑦
,
⑧
,
⑨
,
⑩
(
see
8.2
). During the
process, the symbol of Preset Input (
4.1
) keeps flashing.
Then keep the Storage Button
⑤
pressed for 2 seconds until the the symbol of Preset Input
(
4.1
) disappear. The new temperature and airflow setting is stored into the preset mode for
quick selction.
8.5
Stripping paint
Mount an appropriate accessory.
Set a high air temperature.
Switch the tool on.
Direct the hot air onto the paint to be removed.
When the paint softens, scrape the paint away using a hand scraper.
Do not strip metal window frames, as the heat may be conducted onto the glass
and crack it. When stripping other window frames, use the glass protection
nozzle.
Do not keep the tool directed at one spot too long to prevent igniting the surface.
Avoid collecting paint on the scraper accessory, as it may ignite. If necessary,
carefully remove paint debris from the scraper accessory using a knife.
8.6
Stationary use
Click
Click
Click
Click
Click