Input cable connection (enclose installing diagram) 

1.

 

Every  machine  has  been  disposed  a  power  cable  which  must  be  connected  to 

coordinated  voltage  class  in  compliance  according  to  input  voltage  of  cutting 

machine  .If  cutting  machine  whose  power  voltage  is  220V  is  connected  wrong  to 

AC 380V, that will cause components of inter-machine are burned up. 

2.

 

Make  sure  power  cable  is  connected  to  power  switch  reliably  and  prevent  from 

oxidizing. 

Make sure power voltage is inside the waved range.

 

Output cable connection   

1.

 

Make  sure  tube  of  pressed  air  is  connected  to  copper  connector  by  high-pressure 

rubber tube firmly. 

2.

 

Make  sure  copper  screw  of  another  end  of  torch  is  connected  to  gas-electrify 

integration terminal then tighten them clockwise relation (prevent from leaking gas). 

Mobile plug of another end of earth cable is connected to positive terminal of front 

panel then tighten it. 

3.

 

Make  sure  air  plug  of  torch  is  connected  to  switch  connector  of  panel  (If  it  is 

pilote-arc  cutter,  pilote-arc  cable  of  torch  is  connected  to  terminal  of  pilote-arc 

wiring column.)

 

CHECK 

1.

 

Check if cutting machine is grounded reliably according to standard. 

2.

 

Check if all connectors are connected firmly. 

3.

 

Check if power voltage is correct.

 

OPERATION 

1.

 

Open the power switch of front panel; make the power switch is in 

on

 position .At 

this time indicator of power switch is on. Screen will show the current volume. 

2.

 

Adjust  the  gas  pressure  and  make  it  is  adequate  to  machine,  open  the  valve  of 

pressed air. 

3.

 

Press  the  control  knob  of  torch,  electromagnetic  valve  is  starting,  sound  of  HF 

arc-striking  can  be  heard  and  burner  of  torch  should  flow  out  gas  (Burner  of 

pilote-arc cutter should spurt fire) 

4.

 

Make  sure  cutting  current  is  adequate  to  machine  according  to  thickness  of  cutting 

piece. 

Содержание CUT 40

Страница 1: ...PLASMA CUTTER OWNER S MANUAL MODEL CUT 40 60 POWER v MOS CONTROLIED PLASMA CUTTING POWER SUPPLY ...

Страница 2: ...wer is used volume and weight of main transformer has reduced substantially and efficiency has been increased by 30 Piloting arc system can strike arc easily with principle of high frequency oscillation It has functions that it can supply gas ahead and turn off gas delayed cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Energy saving and no noise 5 High c...

Страница 3: ...e phase 220V 15 Three phase 380V 15 Rated input power KVA 6 6 7 9 No load voltage v 230 295 Rated input current A 30 12 Rated output voltage v 96 104 Duty cycle 60 60 Pilot arc model HF oscillating HF oscillating Burner inter diameter mm 1 0 1 2 Pressure of air compressor kg 4 5 4 5 Thickness mm 1 12 1 20 Weight kg 9 19 Dimensions mm 371 153 232 480 204 303 ...

Страница 4: ...YF 22 A2 3 The panel picture above is for reference only If any difference with the real machine please follow with the real machine INSTALLATION ...

Страница 5: ...n 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the meter is as follow The volume in the picture is 6 kg 7 If the water in the gas filtering bottle is too much please turn on t...

Страница 6: ...obile plug of another end of earth cable is connected to positive terminal of front panel then tighten it 3 Make sure air plug of torch is connected to switch connector of panel If it is pilote arc cutter pilote arc cable of torch is connected to terminal of pilote arc wiring column CHECK 1 Check if cutting machine is grounded reliably according to standard 2 Check if all connectors are connected ...

Страница 7: ... dust or corrosive gas in the air SAFTY 1 Make sure the working area is adequately ventilated Cutting machine is light and its structure is compact and the electromagnetic fields generated the high current So natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 ...

Страница 8: ... tip must not connect to work piece directly when user is cutting Torch should be inclined and it is 1 mm from inter hole of copper tip to work piece in order to protect copper tip 2 As arc supporting cutting machine if arc supporting frequency is down or there is no arc supporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAIN...

Страница 9: ...and fan is working However press control knob of torch there is no HF arc striking sound and inter red diode is lit 1 Check if MOS K1170 of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indicator is lit and fan and electromagnetic valve are working However there is no sound of HF arc striking and inter red diode is ...

Страница 10: ...here is no DC 24V output 3 Open the air switch fan and indicator are working Press knob of torch electromagnetic valve is starting there is no sound of HF arc striking and red diode is not lit There is some fault in part of arc striking such as 1 It is too far between discharge tip or there is adhesion in discharge tip 2 Primary coil of arc striking transformer is damaged or poor contact 3 Check i...

Отзывы: