                                                                                                                                                            YF-22    A2 
 

9

Check Fault 

CUT 60

 

 
 
 
 
 

 
 
 
 

Faults 

Resolvable Methods 

1.Open  the  air  switch,  fan  does  not  work  and 

there is  nothing  in indicator  .knob  of  torch  is  out 

of working . 

1.Part  of  assistant  power  of  control  panel  is  damaged  and 

there is no DC 24

V

 output . 

2.Open the air switch ,fan is working .Press knob 

of  torch  ,electromagnetic  valve  is  working  ,there 

is no sound of HF arc-striking and red diode is lit. 

1.

 

Circuit of torch is broken . 

2.

 

Knob of torch is damaged . 

3.

 

Part  of  assistant  power  is  damaged  and  there  is  no  DC 

24

V

 output . 

3.Open  the  air  switch  ,fan  and  indicator  are 

working  .  Press  knob  of  torch  ,  electromagnetic 

valve  is  starting  ,there  is  no  sound  of  HF 

arc-striking and red diode is not lit . 

There is some fault in part of arc-striking ,such as: 

1.

 

It is too  far  between  discharge tip  or  there  is adhesion in 

discharge tip . 

2.

 

Primary  coil  of  arc-striking  transformer  is  damaged  or 

poor contact . 

3.

 

Check if four times voltage rectifier diode is stricken . 

4.

 

Check if HF electric capacity 102/10KV is leaking . 

5.    Relay is damaged . 

4.As 

arc-supporting 

cutter 

such 

as 

CUT60/70/100/120  ,if  it  can  not  support  arc  or 

support arc weakly . 

1.

 

Wipe the electrode by abrasive cloth . 

2.

 

Magnify arc-striking tip suitably . 

Содержание CUT 40

Страница 1: ...PLASMA CUTTER OWNER S MANUAL MODEL CUT 40 60 POWER v MOS CONTROLIED PLASMA CUTTING POWER SUPPLY ...

Страница 2: ...wer is used volume and weight of main transformer has reduced substantially and efficiency has been increased by 30 Piloting arc system can strike arc easily with principle of high frequency oscillation It has functions that it can supply gas ahead and turn off gas delayed cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Energy saving and no noise 5 High c...

Страница 3: ...e phase 220V 15 Three phase 380V 15 Rated input power KVA 6 6 7 9 No load voltage v 230 295 Rated input current A 30 12 Rated output voltage v 96 104 Duty cycle 60 60 Pilot arc model HF oscillating HF oscillating Burner inter diameter mm 1 0 1 2 Pressure of air compressor kg 4 5 4 5 Thickness mm 1 12 1 20 Weight kg 9 19 Dimensions mm 371 153 232 480 204 303 ...

Страница 4: ...YF 22 A2 3 The panel picture above is for reference only If any difference with the real machine please follow with the real machine INSTALLATION ...

Страница 5: ...n 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the meter is as follow The volume in the picture is 6 kg 7 If the water in the gas filtering bottle is too much please turn on t...

Страница 6: ...obile plug of another end of earth cable is connected to positive terminal of front panel then tighten it 3 Make sure air plug of torch is connected to switch connector of panel If it is pilote arc cutter pilote arc cable of torch is connected to terminal of pilote arc wiring column CHECK 1 Check if cutting machine is grounded reliably according to standard 2 Check if all connectors are connected ...

Страница 7: ... dust or corrosive gas in the air SAFTY 1 Make sure the working area is adequately ventilated Cutting machine is light and its structure is compact and the electromagnetic fields generated the high current So natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 ...

Страница 8: ... tip must not connect to work piece directly when user is cutting Torch should be inclined and it is 1 mm from inter hole of copper tip to work piece in order to protect copper tip 2 As arc supporting cutting machine if arc supporting frequency is down or there is no arc supporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAIN...

Страница 9: ...and fan is working However press control knob of torch there is no HF arc striking sound and inter red diode is lit 1 Check if MOS K1170 of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indicator is lit and fan and electromagnetic valve are working However there is no sound of HF arc striking and inter red diode is ...

Страница 10: ...here is no DC 24V output 3 Open the air switch fan and indicator are working Press knob of torch electromagnetic valve is starting there is no sound of HF arc striking and red diode is not lit There is some fault in part of arc striking such as 1 It is too far between discharge tip or there is adhesion in discharge tip 2 Primary coil of arc striking transformer is damaged or poor contact 3 Check i...

Отзывы: