To prolong the life of the battery, only
charge the battery when the low-battery
light flashes.

NOTE:
Your Nebulizer is equipped with two battery
lamps. Both are positioned on the front of
the unit.

1) A flashing red battery

light, 

Fig. 6, indicates

proper AC connection
and shows that the 
battery is being charged.
NOTE: This lamp has a
second function during oper-
ation. It indicates the lowest
nebulization level, 

Fig. 10.

2) If this lamp, 

Fig. 7, changes from green

to red during use, the rate of nebulization 
will decrease, then cease, indicating that
the battery needs to be charged. If this
occurs,

(1) Press the POWER button to turn off.
(2) Flip the switch at the

bottom to the
OFF/CHARGE posi-
tion.

(3) Replace with a fully

charged battery or
connect to the AC
adapter.

(4) Flip the switch at the bottom to the

ON position.

(5) Press the POWER button and 

continue treatment.

To start the unit,

IMPORTANT! Your unit has two ‘POWER’
switches. One on the
front of the unit, 

Fig. 8, 

and the other on the 
bottom, 

Fig. 9.

1.  Place the unit on a

solid, flat dry surface
making sure that the
water reservoir and
medicine  cup have
been properly filled and the mouth nozzle
or other attachments are properly connect-
ed to the cover.

2.  Flip the switch at the bottom to the “ON’

position. The LED indicator on the front of
the unit will illuminate.

3. Press the ‘POWER’ button.

To adjust the airflow, and nebulizer
rate, 

1. Your Ultrasonic Nebulizer has 3 airflow 

settings: High, Medium and Low.

2. Based on instructions

from your physician
and/or respiratory 
therapist, press the 
airflow button to adjust
the airflow volume. The
Airflow Volume Indicator
Lights will show the
level (high, medium or
low) selected, 

Fig. 10.

To begin a treatment,

1. Follow the instructions provided by your 

physician and/or respiratory therapist.

2. Your Nebulizer is designed to start at a 

lower atomization rate in the beginning and
will become stronger after a few minutes.

NOTE: Although many medications are deliv-
ered within six minutes, thicker medications
will take longer to nebulize. The viscosity of
the medication and airflow setting may result
in longer treatment times and reduced battery
life between recharges.

Remember:

•  Keep your eyes away from the output of 

medication mist.

•  If any discomfort or abnormality occurs,

stop using the unit immediately.

•  Do not tilt or shake the unit when in 

operation.

•  Opening the cover during operation may

cause a severe injury.

To end a treatment,

1.  When the treatment has ended, press the 

POWER button. Postion the switch at the
bottom to the OFF/CHARAGE position.
Otherwise, your unit will automatically shut
off after approximately 10 minutes of 
non-use.

2.  Unplug the adapter from the outlet and

detach the adapter plug from the unit’s 
AC port.

3.  Dispose excess medication and water

before disconnecting the battery. 

4.  Allow the unit to cool — approximately 

20-30 minutes.

Remember:
•  The unit should not be used for more than 

30 minutes at a time.

•  Wait 30 minutes before reusing the unit.

Fig. 8

Fig. 6

Fig. 7

POWER

AIR FLOW

Fig. 9

6

Fig. 10

POWER

AIR FLOW

High

Medium

Low

Содержание 40-270-000 MABISMist II

Страница 1: ...ed for use in the treatment of asthma COPD and other respiratory ailments in which an aerosolized medication is required during therapy The MABISMist II Ultrasonic Nebulizer is not intended for use with Pentamidine It is intended for single patient use Federal U S A law restricts this device to sale by or on the order of a licensed physician English Spanish TOLL FREE CUSTOMER CARE HELPLINE 1 800 6...

Страница 2: ...ar use or purpose whether or not the use or purpose has been disclosed to MABIS Healthcare in specifications drawings or otherwise and whether or not MABIS Healthcare s products are specifically designed and or manufactured by MABIS Healthcare for the buyer s use or purposes except for the limited warranty stated above MABIS will not be responsible for any indirect incidental special consequential...

Страница 3: ... unit Do not attempt to remove the transfer cone located in the base of the water reservoir If any abnormality occurs discontinue use until the unit has been examined and repaired The unit should not be left unattended while plugged in Do not use solutions other than water in the reservoir It may damage the transducer Do not tilt or shake the unit when in operation Opening the cover during operati...

Страница 4: ...high humidity Avoid placing the battery on metal or wet surfaces or inside a metal box This may short circuit the battery s positive and negative contact causing the battery to heat up or explode Cleaning Procedures It is important to clean your Nebulizer before the first time it is used and after each use Remember Disconnect the unit from the electrical outlet and never immerse the unit in water ...

Страница 5: ...east 4 ml Only use medications under the instructions of your physician Using the AC adapter or battery pack Your Nebulizer operates by use of the AC adapter or battery pack both included with your Nebulizer Using the AC adapter 1 Insert the adapter plug into the unit s AC port Fig 4 2 Plug the adapter into a standard AC outlet NOTE It is not necessary to install the bat tery pack when using AC vo...

Страница 6: ...w settings High Medium and Low 2 Based on instructions from your physician and or respiratory therapist press the airflow button to adjust the airflow volume The Airflow Volume Indicator Lights will show the level high medium or low selected Fig 10 To begin a treatment 1 Follow the instructions provided by your physician and or respiratory therapist 2 Your Nebulizer is designed to start at a lower...

Страница 7: ...firmly and properly properly mounted to the motor shaft A flashing red This is normal see Using the light on the Battery Pack The flashing bottom lamp light indicates proper AC when the AC connection and will change to adapter is green when the battery is connected fully charged The top light The battery needs to be changed from charged Nebulization will green to red decrease and then cease during...

Страница 8: ... Forest IL 60045 USA Toll Free Customer Care Helpline 800 622 4714 www mabis net E mail nebinfo mabis net Phone 847 680 6811 Fax 847 680 9646 8 Unit Specifications Name and model number MABISMist II Ultrasonic Nebulizer 40 270 000 Power 100 120 VAC or 220 240 VAC 50 60 Hz Power Consumption Approximately 10W Ultrasonic Frequency 2 5 MHz Nebulization 3 speed adjustable Partical Size 5 m MMAD Medicin...

Отзывы: