Limited Lifetime Warranty

MABIS Healthcare guarantees that its Digital Blood Pressure Monitor will be free from

manufacturing defects under normal use for as long as the original purchaser owns the

product. This warranty covers only normal use, and does not apply to use in any clinical or

commercial applications. This warranty does not cover batteries or other power sources that

may be provided with or used with the Digital Blood Pressure Monitor. This warranty is

voided if the Digital Blood Pressure Monitor is misused or abused in any

manner.

If the Digital Blood Pressure Monitor fails to operate during the time the original

purchaser owns it, return it postage prepaid along with $5.00 for return shipping and

insurance to: MABIS Healthcare, Attn: Repair Department, 1931 Norman Drive South,

Waukegan, IL 60085. When returning a product, please also include a letter with your name,

address, phone number and brief description of the specific problem. Please carefully

package the product to avoid any damage that may occur while in the transit. Packaging

insurance with returned receipt is recommended. MABIS will repair or replace the defective

unit at the option of MABIS Healthcare. Repair or replacement of the defective unit, at the

warrantorʼs option, is the sole remedy under this warranty.

ANY IMPLIED WARRANTIES WHICH THE PURCHASER MAY HAVE ARE LIMITED IN

DURATION TO THE TIME THAT THE ORIGINAL CONSUMER PURCHASER OWNS THE

PRODUCT. Some states do not allow limitations or how long an implied warranty lasts, so

the above limitation may not apply to you.

This warranty constitutes the warrantorʼs only responsibility and obligation to repair and/or

replace materials or components, or refund the purchase price.

MABIS will not be

responsible for any indirect, incidental, special, consequential, or punitive damages

or other loss,

including, but not limited to, damage to or loss of other property or

equipment and personal injuries, whether to purchaser or others. MABIS shall in no event

be liable to the purchaser for any amount in excess of the cost of repair and/or

replacement of the unit, or the purchase price of the unit. Some states do not allow the

exclusive or limitation of incidental or consequential damages, so the above limitation or

exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary

from state to state.

Toll-Free Customer Care Help Line: 1-800-622-4714

Monday - Friday 8:00 am - 4:30 pm CST

1931 Norman Drive South • Waukegan, IL 60085

847-680-6811 • FAX 847-680-9646 • www.mabis.net

Index

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Product Identification & Caution . . . . . . . . . . . . . . . . . . . 4

Why Monitor Your Blood Pressure at Home? . . . . . . . . 5

General Blood Pressure Information . . . . . . . . . . . . . . 5-7

Important Information Before Use . . . . . . . . . . . . . . . . . 7

World Health Organization (WHO) Indicator . . . . . . . . . 8

Irregular Heartbeat Detection . . . . . . . . . . . . . . . . . . . . . 9

Battery Installation/Replacement . . . . . . . . . . . . . . . . . 10

Setting the Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Applying Your Blood Pressure Cuff . . . . . . . . . . . . . . . 12

Taking Your Blood Pressure Reading . . . . . . . . . . . . . 13

Recalling Measurements in Memory . . . . . . . . . . . . . . 14

Description of Display Symbols . . . . . . . . . . . . . . . . . . 15

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 16

Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 16

Sample Blood Pressure Log . . . . . . . . . . . . . . . . . . 17-18

Introduction

To achieve the maximum benefit from your blood pressure monitor, we recommend that you

first consult with your physician or trained healthcare professional.

Thank you for purchasing a MABIS Semi-Automatic Digital Blood Pressure Monitor. With

proper care and use, your monitor will provide you with many years of reliable readings.

The method of measurement that your Semi-Automatic Monitor uses is called the oscillometric

method. The monitor detects your bloodʼs movement through the artery in your arm and

converts the movements into a digital reading. The oscillometric method does not require a

stethoscope, making the monitor easy to use.

Blood pressure readings determined with this device are equivalent to measurements

obtained by a trained observer using the cuff/stethoscope auscultation method, within the

limits prescribed by the American National Standard for Electronic or Automated

Sphygmomanometers.

Содержание 04-391-001

Страница 1: ...INSTRUCTION MANUAL 04 391 001 Please read this instruction manual completely before operating this unit English Spanish Premium Digital Blood Pressure Arm Monitor Semi Automatic ...

Страница 2: ...onal injuries whether to purchaser or others MABIS shall in no event be liable to the purchaser for any amount in excess of the cost of repair and or replacement of the unit or the purchase price of the unit Some states do not allow the exclusive or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rig...

Страница 3: ...ls of the blood vessels throughout your body Your heart which is the center of the circulatory system provides the force for the blood to flow or circulate When your heart contracts or beats the blood is forced through the blood vessels increasing the pressure This is the highest pressure in the cycle or what is referred to as SYSTOLIC blood pressure In between beats your heart relaxes and your bl...

Страница 4: ...ysiological characteristics 10 This device is intended for adult use 11 The inflation or deflation process can be stopped by pressing the Release button 7 Blood pressure is measured in millimeters mm of mercury Hg and is generally recorded with the systolic pressure 120 listed first and the diastolic pressure 80 listed second The numbers are typically separated by a slash mark as shown Both pressu...

Страница 5: ...appear on the display Fig 1 NOTE Please consult with your physician or trained healthcare professional for further information regarding an irregular heartbeat and if this symbol appears frequently at the end of a reading Stage 3 Hypertension Systolic pressure 180 mmHg or Diastolic pressure 110 mmHg Stage 2 Hypertension Systolic pressure 160 179 mmHg or Diastolic pressure 100 109 mmHg Stage 1 Hype...

Страница 6: ...tment matching the indicated polarity symbols Fig 1 3 To close match up and connect the bottom hooks of the cover then push the top end NOTE Replace the batteries when the Low Battery symbol appears on the display or when the display remains blank when the POWER button is pressed 4 It is recommended to remove the batteries if the unit will not be used for an extended period of time AC Power Adapte...

Страница 7: ... range A different sized cuff is needed if the Index mark is outside of the OK range Taking Your Blood Pressure Reading Proceed only after reading the previous sections of this manual 1 Position the monitor on a flat stable surface with the digital display panel in view Insert the cuff tubing connector into the left side of the monitor Fig 1 2 Rest your elbow on a solid surface with your palm faci...

Страница 8: ...he saved measurements After youʼve scrolled through all the readings the unit will automatically turn off NOTE When the number of readings exceeds 60 the oldest data will be replaced with the new record To erase all stored measurements 1 Press and release the MEMORY button The unit will display how many measurements are stored within the bank 2 Press and hold down the MEMORY button until two horiz...

Страница 9: ...tic Premium Digital Blood Pressure Arm Monitor 04 391 001 Display system Digital display LCD Measuring method Oscillometric Power source 4 AA batteries Measuring range Pressure 0 300 mmHg Pulse 30 180 beats minute Accuracy Pressure 3 mmHg Pulse 5 of reading Inflation Manual Inflation Deflation Automatic Pressure Release Valve Manual fast release Memory Built in memory enabling display of up to 60 ...

Страница 10: ...Blood Pressure Log Name Age Weight Date Time 240 220 200 180 160 140 120 100 80 60 Pulse Body Con dition mmHg 18 ...

Отзывы: