SERVICE MANUAL
Model:CHM200PB1
20
Issue 2017-6-03
Rev. REF1706S004V0
Foods defrosting
Temperature control OFF or
Min or 0 positions.
Move the control to a temperature setting.
Freezer is unplugged.
Push the plug completely into the outlet.
The fuse is blown/circuit
breaker is tripped.
Replace fuse or reset the breaker
Door/lid left open.
Check to see if package is holding door/lid
open.
Too frequent or too long
door/lid openings.
Reduce the time of opening the door/lid
Freezer
temperature too
cold
Temperature control set too
cold.
See About the operation of the freezer
Fast Freeze switch is in the
ON position or has run for too
long (on some models)
About the operation of the freezer
Moisture forms on
outside of cabinet
Not unusual during periods of
high humidity
Wipe surface
Interior light does
not work (on some
models)
No power at outlet.
Replace fuse or reset the breaker
Freezer is unplugged.
Push the plug completely into the outlet.
Light bulb burned out.
Replace bulb.
Door/lid wont fully
close by itself
Package holding door/lid
open.
Store only corrects quantity of food.
Slow starting time
after being off
Built-in overload product.
Store only corrects quantity of food.
Excessive frost
build-up
Door/lid left open.
Check to see if package is holding door/lid
open.
Too frequent or too long
door/lid openings.
Reduce the time of opening the door/lid
Not unusual during periods of
high humidity
Put the freezer to suitable place
Содержание CHM200PB1
Страница 16: ...SERVICE MANUAL Model CHM200PB1 16 Issue 2017 6 03 Rev REF1706S004V0 6 2 Refrigeration flow scenograph...
Страница 18: ...SERVICE MANUAL Model CHM200PB1 18 Issue 2017 6 03 Rev REF1706S004V0 7 2 Wiring diagram...
Страница 22: ...SERVICE MANUAL Model CHM200PB1 22 Issue 2017 6 03 Rev REF1706S004V0 8 2 2 Poor cooling...