M2M MCF-LW12TERPM Скачать руководство пользователя страница 1

 

m2m Germany GmbH | Am Kappengraben 18-20 | 61273 Wehrheim | 06081 5873860 

 
 

Table of Contents

 

MCF-LW12TERPM Operating Manual

 

Important safety information

 

Read this manual before attempting to install the device! Failure to observe recommendations 
included in this manual may be dangerous or cause a violation of the law. The manufacturer 
will not be held responsible for any loss or damage resulting from not following the 
instructions of this operating manual.

 

Do not dismantle or modify in any way.

 

The device is not intended to be used as a reference sensor, and enginko Srl will not be held liable for 
any damage which may result from inaccurate readings.

 

Avoid mechanical stress

 

Do not use any detergent or alcohol to clean the device.

 

Содержание MCF-LW12TERPM

Страница 1: ...may be dangerous or cause a violation of the law The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of this operating manual Do not dism...

Страница 2: ...be collected separately from other waste Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately To remove the batteries refer to...

Страница 3: ...Ah Li SOCl2 primary battery as backup 30 days of operation with no sun with main battery fully charged 20 hours of of direct sunlight Wall or pole mounting Storagetemperature range 30 80 C Workingtemp...

Страница 4: ...data after the sensor has restarted Configuration can be done only via NFC No USB port available for the user 2 4 Power ON OFF The sensor is shipped completely off to prevent battery consumption duri...

Страница 5: ...81 5873860 At the first power on sensor will take from 1 to 5minutes to give an effective measure of PM In case of long period inactivity if necessary is possible to shut off again the sensor to preve...

Страница 6: ...ERPM is provided with one Li SOCl2 battery pack as backup Code Description MCF 1S2PE7200mAh battery pack With this battery the sensor can run for 1 year with the rechargeable battery completely discha...

Страница 7: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860...

Страница 8: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Updatethe sensor with LoRaTool...

Страница 9: ...ssage 3 Measures 3 1 Period Period is the interval in minutes between one measure and the next one The sensor sends one measures for every transmission Value can be between 15 and 65535 minutes defaul...

Страница 10: ...also be set with downlink command 3 4 Humidity 3 5 PM The PM measurement principle is based on laser scattering This technology together with high quality and long lasting components enables precise...

Страница 11: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 4 LoRaWAN network The sensor is compliant with LoRaWAN specification 1 0 2 regional 1 0 2b...

Страница 12: ...5000000001 AppKey on request 5 ABP requires writing to the device of NwkSkey AppSkey DevAddr The device exits factory activated with NONE mode On request devices can be shipped aleady activated Note i...

Страница 13: ...ult enabled Normally sensor asks for a time sync at every power on uplink starting with 01 or if enabled once a week Ifnot handled in the right way can cause aunnecessary battery consumption Please ch...

Страница 14: ...Passwords The device can be protected by passwords to avoid unauthorized persons to read data or modify parameters As default passwords are equal to 0 Allowed values range from 0 to 999999999 only num...

Страница 15: ...ermany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Once the passwords are setted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the d...

Страница 16: ...configure the device using an XML file instead to manually adjust the parameters for details about the file format please ask to enginko This is very useful especially in case of multiple devices conf...

Страница 17: ...want to overwrite XLS is prevailing on the XML so if both files are enabled if the DevEUI of the device matches one of the DevEUIs in the XLS file LoRa parameters will be setted from this one These co...

Страница 18: ...or payload descriptions uplinks and downlinks format and available commands please refer to this document 9 Maintenance Keep the surfaces clean and remove dust from the solar panel with a damp cloth w...

Страница 19: ...RPM US enginko LoRaWAN outdoor PM and environmental sensor US902 928 MCF LW12TERPM AUenginko LoRaWAN outdoor PM and environmental sensor AU915 928 11 Declaration of conformity Hereby enginko Srl decla...

Отзывы: