4. Measures

 

4.1 Period

 

Period is the interval (in minutes) between one measure and the next one. The sensor sends two measures for every transmission (each one with its own timestamp),  
so the messages interval is twice the period value. Value can be between  10 and 65535 minutes.

 

Period interval can be set with App or with downlink command.

 

The device sends extra reports when the measurement changes in accordance with the set thresholds.

 

4.2 Temperature

 

4.3 Pressure

 

4.3.1 Altitude compensation

 

Содержание MCF-LW12CO2E

Страница 1: ...irective 2012 19 EU of the European Parliament on waste electrical and electronic equipment WEEE and pursuant to and in accordance with Article 20 of the Directive 2013 56 EU of the European Parliamen...

Страница 2: ...ime measurement message Battery powered with 4 years of battery life SF 12 10minutes reading period Battery capacity included 21600mAh NFCfor node configuration FW update and data reading Indoor insta...

Страница 3: ...or has restarted 2 3 Power ON OFF The sensor is shipped completely off to prevent battery consumption during storage It istherefore necessary to carry out afirst power on prior to commissioning There...

Страница 4: ...LoRaWAN not configured Slow flashing Joining Sending Receiving Steadystate Data error Connection error 2 5Battery This sensor contains lithium battery which must be disposed of separately MCF LW12CO2E...

Страница 5: ...removethe back panel of the sensor with asmall screwdriver detach the batteries from the electronic board batteries are secured with dual locking tape and disconnect both from the connectors Connect t...

Страница 6: ...ation you need aunique reset code that must be requestedto enginko please provide the DevEUI of the sensor when you ask for that code Atthe end of the procedure the battery level displays 100 2 6Firmw...

Страница 7: ...s Onthe MCF LW12CO2E there are three indicators in the front of the device green yellow and red Light status isrelated to the values of CO2 only bVOC only or both depending on enabled thresholds 3 1 B...

Страница 8: ...ds two measures for every transmission each one with its own timestamp sothe messages interval istwice the period value Value can be between 10and 65535 minutes Period interval can be set with App or...

Страница 9: ...ions must be compensated Setthe right altitude value with LoRa Tool app Valuecan be from 300 to 3000 meters Altitude can also be set with downlink command 4 4Humidity 4 5Lux 4 6VOC Asdefault the devic...

Страница 10: ...irst power on 4 7 1 Calibration Due to the internal automatic calibration algorithm enabled as default the sensor must be exposed to true fresh air environment at least once aweek Ifsuch an environmen...

Страница 11: ...are falling below the negative thresholds leds change accordingly and the device sends anew uplink with the new leds status and the latest measures Thresholds can be enabled disabled and set via NFC w...

Страница 12: ...IAQ thresholds Airquality can be expressed as IAQ index or ppb and thresholds unit of measurement will change accordingly ForIAQ values can be set from 0to 500 Whenthe unit of measurement isppb thres...

Страница 13: ...915000000001 AppKey on request 5 ABP requires writing to the device of NwkSkey AppSkey DevAddr The device exits factory activated with NONE mode On request devices can be shipped aleady activated Note...

Страница 14: ...y can cause aunnecessary battery consumption battery life 2 years Please check chapter 2 1 UnConfirmed setfor unconfirmed uplinks default confirmed uplink Singlejoin day setfor to allow only onejoin p...

Страница 15: ...tted to gain access from LoRa Tool to the sensor open the App and set the right values before reading from the device To bring back the sensor to factory default and reset the passwords a reset code m...

Страница 16: ...dditional XLS file ispossible to load different LoRa configuration parameters Activation Type AppKey AppEUI NetKey DevAddress Band Private option for each sensor based on DevEUI Whenthe sensor isappro...

Страница 17: ...ration of conformity Hereby enginko Srl declares that MCF LW12CO2E complies with the essential requirements and other relevant provisions of Directive 2014 53 EU 11 Contacts enginko Srl ViaRoma 3I 280...

Отзывы: