Once provisioned on a LoRaWAN® network, the device sends the measures to the server via uplink.
4 I/O
As default, the device sends a message every time an input or an output changes.
A downlink with new output status forces the device to send back an unplink with the new status. If the output status is the
same of current one, the sensor will not send back any message.
Downlink examples (hex):
turn ON the output:
turn off the output:
receive the current status: 0400 0000 0000 0000 0000
Is possible to set a period (in minutes) to receive a recurrent periodic message with the I/O status.
4.1 Input
Off voltage
0÷2Vac 50/60Hz
On Voltage
250Vac 50/60Hz
3mA typ
Max frequency (as counter) 2 Hz
0400 0
1
00 0000 0000 0000
0400 0000 0000 0
1
00 0000
Maximum input voltage
Input current
> 8Vac 50/60Hz