Once the passwords  are setted, to gain access from LoRa Tool to the sensor, open the App:

 

and set the right values before reading from the device:

 

To bring back the sensor to factory default and reset the passwords,  a reset code must be requested to enginko (please  
provide the DevEUI of the sensor when you ask for that code).

 

7 Configuration  file

 

Содержание enginko MCF-LW12MET

Страница 1: ...onot dismantle or modify in any way Avoidmechanical stress The device is not intended to be used as areference sensor and enginko Srl will not be held liable for any damage whichmay result from inaccu...

Страница 2: ...100 240Vac 50 60 Hz Metering of a 230Vac 16Amp Load active reactive and apparent energy Class 0 2s Configurable default power on status Instantaneous reading of active reactive and apparent power volt...

Страница 3: ...ce must be placed where the LoRaWAN signal coverage is good SF 7 optimal SF 12 weak 2 3 Power supply Connectthe power supply to pins L LINE and N LINE Valid range is 100Vac to 240Vac 50 60Hz 2 4 Confi...

Страница 4: ...N LINE The power status is visible onthe red green led Always validate your settings by reading the NFC data after the sensor has restarted Configuration can be done only via NFC No USB port availabl...

Страница 5: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860...

Страница 6: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 Update the sensor with LoRaTool...

Страница 7: ...bH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 During the update do not move the smartphone untill the end message 3 Measures On each reading of the sensor by LoRaTool the measures are shown on...

Страница 8: ...k with the new status If the output status is the same of current one the sensor will not send back any message Downlink examples hex turn ON the output turn off the output receive the current status...

Страница 9: ...nd one to turn off the ouput is possible to send a duration command for example to drivevalves or heaters As application example to safely turn on an output send a ON pulse command for a defined time...

Страница 10: ...ate and XLS file that can be downloaded by downlinks 4 3Wiring examples Load connected to the same supply of the sensor connected to the relay output normally open contact and digital input drivenby a...

Страница 11: ...20 61273 Wehrheim 06081 5873860 Energymonitoring of a load connected to the same supply of the sensor driven by the relay normally open contact 5 LoRaWAN network The sensor is compliant with LoRaWAN...

Страница 12: ...3 OTAAMCF88 Over the air activation fixed keys JoinEUI 904e915000000003 AppKey on request 4 OTAAENGINKO Over the air activation fixed keys JoinEUI 904e915000000003 AppKey on request 5 ABP requires wri...

Страница 13: ...hange it only if Objenious network is used default_ any Network type LoRa syncword can be setted as private 0x12 instead public 0x34 butthe NS must be setted accordingly default public Band select the...

Страница 14: ...ystem leds default enabled Input counter setto enable the pulses counter funcion default disabled Singlejoin day set for to allow only one join per day default multiple join allowed Countersperiod min...

Страница 15: ...measures in minutes Clocktimed setto sincronize the reading with the internal clock default off 230 120Vac set is line voltage is 120Vac default 230Vac Send all metering value setto send cumulative a...

Страница 16: ...egative thresholds the device sends anew uplink with the latest measure Thresholds can be enabled disabled and changed via LoRaTool or with downlinks 6 Passwords The device can be protected by passwor...

Страница 17: ...n access from LoRa Tool to the sensor open the App and set the right values before reading from the device To bring back the sensor to factory default and reset the passwords areset code must be reque...

Страница 18: ...n is needed at least one XML file with the parameters to set Settings on this file will be applied to all the sensors With an additional XLS file is possible to load different LoRa configuration param...

Страница 19: ...etails on files format please ask to enginko 8 LoRaWEB Tool enginkoprovides upon free registration LoRaWEB online tool where for each sensor it is possible to find documentation javascript examples fo...

Страница 20: ...phase metering AS920 925 MCF LW12MET US enginko LoRaWAN mono phase metering US902 928 MCF LW12MET AU enginko LoRaWAN mono phase metering AU915 928 MCF LW12MET WW enginkoLoRa mono phase metering 2 4GH...

Отзывы: