Industrial HMI Touch Panel Hardware Manual
M2I Corporation
11-35, Simin-daero 327beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do 14055, Korea, Tel: +82-70-465-3366, Fax: +82-31-465-3355, www.m2i.co.kr
4 / 22
short circuit, fire, malfunctions. FG Terminal must be used a dedicated ground. Not doing so could result in
malfunctions.
a. Grounding should be the Class 3 grounding. The cable for grounding should be more than 4㎟.
b. grounding point be closed to the products and make short the distance to the ground cable if possible.
■ Installation Precautions
Do not install the location which exceeds allowed temperature. Product can be damaged or shorten the life.
Especially Install environment as below should be avoided.
Do not Install product to the place which the ambient temperature is out of limits, from -10℃ to 50℃ or on the surface
of control board which high pressure equipment is installed.
Do not install to the place where strong shock or vibration continuously have impacted on product.
If the product is left without using in long-term, it must be recharged and stored in room temperature.
The space between back of product and back of control board must be more than 100mm for maintenance
and ventilation.
Use the product indoors only.
Use the product under 2000M altitute.
Power cable’s length should be 3M(10ft) or shorter.
■ Disposal Precautions
When you dispose of product and battery, please treat it as industrial waste. It can create poisonous substances
or explosion.
■ Cell Type Battery Specifications and Exchange
Mounted on mainboard Model MS920SE Battery is not replaced by the user. If the battery has run out of service,
please contact our Customer Support Center for replacement and inspection.
Item
Content
Battery Voltage
DC 3V
Battery Model
MS920SE (lithium / Rechargeable)
Battery lifetime
Permanent (In case of ambient temperature 25℃)
*
Depending on the model specifications are subject to change.
■
All field-wiring connections to this unit shall be from Limited Voltage / Limited Current, below 24Vdc
isolated secondary source with an output fuse, or Class 2.