Premier T-1 Reading Steam Locomotive
18
The special NiCad 2.4v self-charging battery recharges continuously during train
operation and should last for up to five years. The battery is a dry battery that should
not leak or cause any damage to your engine. Depending upon when your engine was
built, it may need to be charged right out of the box. If engine sounds seem distorted
or garbled at low voltages or become silent when power from the transformer is turned
off, test the battery to determine whether it should be recharged or replaced.
Test:
Put the engine in neutral and leave the track voltage at 10-12 volts (high enough
for the lights to shine brightly) for 15 minutes.
Recharge:
If the sounds are improved at the end of the 15-minute test charge, the
battery charge has run down and can be recharged. There are a number of ways you
can do this:
- Leave the engine in neutral with track voltage at 10-12 volts for 6-7 hours so
the battery can fully recharge (if your engine has a smoke unit, be sure it is
turned off).
-Use M.T.H.'s battery recharger (sold separately) that plugs into a wall outlet
and a special port under the engine to recharge the battery overnight without
leaving it on the track.
Replace:
If the sounds are not improved at the end of the 15-minute test charge, it is
time to replace the battery. Available through M.T.H. Parts.
Self Charging Battery Backup
Figure 14
Figure 15
Battery Port