background image

Premier Dreyfuss Hudson Steam Locomotive

Automatic Sound Effects

Certain Proto-Sound 2.0 sound effects automatically play in programmed conventional 
mode conditions:

•Squealing Brakes play any time the engine's speed decreases rapidly.

•Cab Chatter plays at random intervals when the engine idles in neutral.

•Engine Start-up and Shut-down sounds play when the engine is initially 
powered on or is powered off for five seconds or more.

Reset to Factory Default

To override the settings you currently have assigned to the engine and reset it to its 
factory defaults, while in Neutral tap the Horn button quickly once, followed by five 
quick taps of the Bell button, allowing approximately ½ second to lapse between each 
quick button press. Two horn blasts will indicate that the engine has made the change.

Reset

Two Horn Blasts

(indicates change is made)

Repeat to Return

to Normal Condition

Horn

Place 

Engine in 

Neutral

=

Bell

Bell

Bell

Bell

Bell

14

Содержание Premier Dreyfuss HudsonSteam Locomotive

Страница 1: ...With 12 Wheel Tender 3 rail O 42 Diameter 2 rail 36 Radius With PT Tender 3 rail O 72 Diameter 2 rail 54 Radius This engine is also compatible with most AC DC transformers See pages 24 and 25 for a c...

Страница 2: ...Mode Features 10 Passenger Station Announcements PSA 11 Proto Coupler Operation 12 Speed Control 13 Locking Locomotive Into ADirection 13 Reset To Factory Default 14 Automatic Sound Effects 14 Mainten...

Страница 3: ...ory installed on 3 rail versions and packaged seperately in the locomotive box for 2 rail versions Each pickup roller installs with a single phillips screw seen in Figure 1 Once you have configured th...

Страница 4: ...ocomotive when sitting on the track follows the illustration in Figure 3 Failing to properly configure the polarity will result in the locomotive starting in reverse instead of forward or not receivin...

Страница 5: ...n this locomotive on a 3 rail layout may wish to use the M T H Proto Coupler so that they may enjoy the remote uncoupling anywhere on the layout A Proto Coupler and the necessary mounting hardware are...

Страница 6: ...ove at the end of the T Bar Reattach the truck to the tender chassis by inserting the bolster screw Install the speaker and plug it into the white connector Plug the Proto Coupler to the black connect...

Страница 7: ...th Sides Lubricate Axle Bushings L Figure 7 Lubrication Points on the Locomotive Priming the Smoke Unit When preparing to run this engine add 15 20 drops of smoke fluid through the smokestack We recom...

Страница 8: ...draw bar between the engine and tender The draw bar hole located farthest from the tender is for applications such as display The second hole is for normal operation on the track At this point you ar...

Страница 9: ...ase the Bell button To turn the bell off press and release the Bell button again The bell will continue to ring from the time you turn it on until you press and release the button again to turn it off...

Страница 10: ...ns of each feature before using it To use these buttons to activate features rather than to blow the horn or ring the bell you should tap the buttons very quickly with a second pause between button pr...

Страница 11: ...sabled so that the train will not move as you use the Direction button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Horn and Bell buttons until the full PSA sequenc...

Страница 12: ...of the PSA the engine will depart in the next direction of travel as opposed to the direction it was traveling before entering Neutral Proto Coupler Operation This locomotive is equipped with one or...

Страница 13: ...dicate that the engine has made the change Repeat the 1 horn 2 bells code to return it to the other condition You will want to do this during the initial neutral upon start up if you ever couple this...

Страница 14: ...nitially powered on or is powered off for five seconds or more Reset to Factory Default To override the settings you currently have assigned to the engine and reset it to its factory defaults while in...

Страница 15: ...locomotive s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first To access the gear box and axles do t...

Страница 16: ...e you may need to replace them at some point 1 Remove the side rods from the wheels in order to slip the new tire over the grooved drive wheel Make sure to note the position of all rods before removin...

Страница 17: ...groove properly 6 Reinstall the side rods in the same positions as noted Failure to align rods may cause binding or damage to the drive system One set of replacement tires is packaged with your model...

Страница 18: ...vailable directly from the M T H Parts Department 1 Remove boiler shell by removing the 4 Body Mount Screws shown in Figure 12 2 Disconnect wires from inside boiler 3 Unplug light bulb connector 4 Rem...

Страница 19: ...ute test charge the batteries charge has run down and can be recharged There are a number of ways you can do this Leave the engine in neutral with track voltage at 10 12 volts for 6 7 hours so the bat...

Страница 20: ...nterior engine components If you choose not to add the fluid or have already added the fluid but choose to run smoke free turn off the smoke unit switch located under the water hatch on the right side...

Страница 21: ...nting screws shown in Fig 11 on pg 14 Premier Dreyfuss Hudson Steam Locomotive 1 Once the boiler has been removed remove the inspection cover See figure 18 Inspect the wick if it is darkly discolored...

Страница 22: ...Charging Battery Back Up section of these instructions for how to test recharge and if necessary replace the battery Coupler Remedy When I try to fire the coupler FYS starts The Proto Coupler won t l...

Страница 23: ...s running The engine won t lock into forward neutral or reverse The engine maybe locked into the neutral position Follow the procedure in the Lock into a Direction section to unlock the engine s direc...

Страница 24: ...att Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee...

Страница 25: ...Electronic Electronic Recommended DC Power Supplies Proto Sound 2 0 is designed to work with most standard DC power supplies and AC transformers The following charts lists the recommended DC and AC tr...

Страница 26: ...ingle button mutes or unmutes all DCS controlled locomotives user defined actions including sound lights and smoke Proto Dispatch Operation Public Address like feature allows users to speak through lo...

Страница 27: ...er you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instructions carefully before returning a...

Отзывы: