![M-system W5FV Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/m-system/w5fv/w5fv_instruction-manual_3315306003.webp)
W5FV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
EM-8515 Rev.3 P. 3 / 4
RANGE CONFIGURATION
■
FRONT VIEW
5
4
3
2
1
11
10
9
8
7
6
ON
1 2 3 4 5 6 7 8
Input Range
DIP SW (SW1)
Output Range
DIP SW (SW2)
Zero Adj.
Span Adj.
• Output 2
*
Zero Adj.
*
Not provided for single output type.
Span Adj.
• Output 1
■
INPUT RANGE DIP SW
Input exceeding the maximum value of each input range
may destroy the transmitter. Be sure to confirm the setting
range before applying input signals.
INPUT RANGE
SW1
1
2
3
4
5
6
7
8
4 – 20mA
■
■
■
0 – 20mA
■
■
■
0 – 10mA
■
■
■
0 – 60mV
■
0 – 100mV
■
■
0 – 1V
■
■
0 – 10V
■
■
■
0 – 5V
■
■
1 – 5V
■
■
-10 – +10V
■
■
■
-5 – +5V
■
■
■
■
= ON, Blank = OFF
■
OUTPUT RANGE DIP SW
Only Output 1 is field-configurable. Specify Output 2 range
when ordering.
OUTPUT RANGE
SW2
1
2
3
4
5
6
7
8
4 – 20mA
■
■
■
■
■
0 – 20mA
■
■
■
■
0 – 10V
■
■
■
■
0 – 5V
■
■
■
■
1 – 5V
■
■
■
■
■
-10 – +10V
■
■
-5 – +5V
■
■
■
■
= ON, Blank = OFF