R8-NC3

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: 

+81(6)6659-8510  E-mail: [email protected]

EM-9726  P. 6 / 7

 

DATA ALLOCATION MODE 2

•   Output Data

The figure below shows the allocation of data sent from 
the power / network module to the master.

RWr n+0

0_CH1

Module

0_CH2

1_CH1

1_CH2

2_CH1

2_CH2

3_CH1

3_CH2

4_CH1

4_CH2

5_CH1

5_CH2

6_CH1

7_CH1

6_CH2

7_CH2

+2

+4

+6

+8

+10

+12

+14

31_CH1

31_CH2

+62

0

15

•   Input Data

The figure below shows the allocation of data sent from 
the master to the power / network module.

0_CH1

Module

0_CH2

1_CH1

1_CH2

2_CH1

2_CH2

3_CH1

3_CH2

4_CH1

4_CH2

5_CH1

5_CH2

6_CH1

7_CH1

6_CH2

7_CH2

+2

+4

+6

+8

+10

+12

+14

31_CH1

31_CH2

+62

0

15

RWw n+0

16 × m (m = cyclic expansion setting) data areas are available for the R8-NC3.
Field input data is set at the module’s output data area.  The input data area is also secured though not used for an input 
module.  Above figure shows the area when cyclic expansion is “4”, however the module address is up to 15 when cyclic ex-
pansion is “2”.

•   Module Status

RX (n+0) 0 through RX (n+1) 15 indicate that modules are mounted in each slot.
0: mounted; 1:not mounted.

15

0

Module 0
Module 1
Module 2

Module 15

15

0

Module 16
Module 17
Module 18

Module 31

RX(n+0)

RX(n+1)

•   Ready Signal

When cyclic expansion is “2”, RX (n+13) 11 is assigned to Ready signal, when cyclic expansion is “4”, RX (n+27) 11 is assigned 
to Ready signal, which turns to “1” when the internal bus is in normal conditions.

Содержание R8-NC3

Страница 1: ...ox 12W output current 1 6 A Excitation supply 24V DC 10 operational current 10A ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing...

Страница 2: ...4 3 2 1 0 9 8 7 6 Baud Rate Setting 0 156 kbps 1 625 kbps 2 2 5 Mbps 3 5 Mbps 4 10 Mbps front DIP SW Data Allocation Mode SW1 DATA ALLOCATION MODE SW1 1 ON 2 OFF Cyclic Expansion SW2 CYCLIC EXPANSION...

Страница 3: ...ON OFF OFF ON Unable to receive data addressed to the station ON ON OFF OFF OFF ON OFF BL BL ON Performs the interval timed responses but CRC error found in receiving the refresh data ON OFF BL BL OF...

Страница 4: ...nce bond the FE1 terminal to ground Caution FE1 terminal is NOT a protective conductor terminal EXC SUPPLY 24V INTERNAL POWER 5V PC CONFIGURATION JACK WIRING INSTRUCTIONS TENSION CLAMP TERMINAL BLOCK...

Страница 5: ...utput Data The figure below shows the allocation of data sent from the power network module to the master 0 Module 1 2 3 4 5 6 7 8 9 10 11 12 14 13 15 2 4 6 8 10 12 14 30 31 30 0 15 RWr n 0 Input Data...

Страница 6: ...H1 7_CH1 6_CH2 7_CH2 2 4 6 8 10 12 14 31_CH1 31_CH2 62 0 15 RWw n 0 16 m m cyclic expansion setting data areas are available for the R8 NC3 Field input data is set at the module s output data area The...

Страница 7: ...t binary data is used for temperature data With C K temperature unit raw data is multiplied by 10 For example 25 5 C is converted into 255 With F temperature unit the integer section of raw data is di...

Отзывы: