R7K4DH-1-DAC32D

P. 1 / 5

EM-7796-H Rev.1

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Phone: +81(6)6659-8201   Fax: +81(6)6659-8510   E-mail: [email protected]

PNP DISCRETE INPUT & PNP TRANSISTOR OUTPUT 

MODULE, 16 points each

(High-speed Link System, e-CON connector)

MODEL

R7K4DH-1-DAC32D

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Discrete I/O module ...................................................... (1)
  Surface mounter slider ................................................. (2)

 MODEL NO.

Confirm that the model number described on the product is 
exactly what you ordered.

 INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 CONFORMITY WITH EU DIRECTIVE

• Use dual shielded cables (Shinko Seisen Industry Model 

ZHY262 PBA) for the network.  If it is not sufficient, use a 
ferrite core (Kitagawa Industries Model  GRFC-13) for the 
network cable.

• The actual installation environments such as panel con

-

figurations, connected devices and connected wires may 
affect the protection level of this unit when it is integrated 
in a panel system. The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure CE conformity.

 POWER INPUT RATING & OPERATIONAL RANGE

Locate the power input rating marked on the product and  
confirm its operational range as indicated below:
  24V DC rating: 24V DC ±10%, approx. 95mA

 GENERAL PRECAUTIONS

Before you remove the unit or mount it, turn off the power 
supply, input signal and output signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 

in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  close  to  noise  sources  (relay  drive 

cable, high frequency line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.

COMPONENT IDENTIFICATION

 FRONT VIEW

O

N

1

2

3

4

5

6

7

8

SW1

TERM

ON

ON

PWR

+

-

-

+

FE

SNSR.EX

C

×10

×1

STATION ADD.

Power Run

HLS1

HLS2

Status Indicator LED

Station Address Setting Rotary SW

Power Supply / Sensor Exc. Connectors

I/O Connector

Discrete I/O Status Indicator LED

RJ-45 Modular Jack for HLS 

Operating Mode Setting DIP SW (SW1)

Terminating Resistor SW 