INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Remote control relay control module .................................(1)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 

HOT SWAPPABLE MODULES

• Replacing the module does not affect other modules on 

the same base.  Thus, the module can be replaced while 
the power is ON.  However, replacing multiple modules 
at once may greatly change live voltage levels.  We highly 
recommend to replace them one by one.

 

GENERAL PRECAUTIONS

• DO NOT set the switches on the module while the power 

is supplied.  The switches are used only for maintenance 
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

INSTALLATION

Use the Installation Base (model: R3-BSx).

REMOTE CONTROL RELAY CONTROL MODULE

(Do 8 points, tension clamp terminal block)

MODEL

R3S-RR8

Содержание R3S-RR8

Страница 1: ...We highly recommend to replace them one by one GENERAL PRECAUTIONS DO NOT set the switches on the module while the power is supplied The switches are used only for maintenance without the power ENVIR...

Страница 2: ...LED Red when the bus A operates normally Green when the bus B operates normally Amber when both buses operate normally ERR indicator Green LED OFF in abnormality ON in normal operating conditions Inpu...

Страница 3: ...N 0 1 Output 6 OFF 1 1 Output 6 RESET 12 13 0 0 No operation 1 0 Output 7 ON 0 1 Output 7 OFF 1 1 Output 7 RESET 14 15 0 0 No operation 1 0 Output 8 ON 0 1 Output 8 OFF 1 1 Output 8 RESET By setting w...

Страница 4: ...ut 6 ON 11 Reserved 12 0 Feedback input for output 7 OFF 1 Feedback input for output 7 ON 13 Reserved 14 0 Feedback input for output 8 OFF 1 Feedback input for output 8 ON 15 Reserved INPUT DATA BIT 8...

Страница 5: ...bit Word access Input 1 Output 1 Input 2 Output 2 Input 8 Output 8 Input 1 Output 1 Input 2 Output 2 Input 8 Output 8 0 0 I O data length is 16 bit Bit access 2 bits corresponds one I O Each bit in t...

Страница 6: ...B INTERNAL POWER 9 5 11 7 6 8 10 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 COM COM 3 OUTPUT 2 OUTPUT 1 20 2 4 15 1 14 16 18 12 17 19 13 COM COM COM COM COM COM COM COM COM COM BUS CONNECT...

Страница 7: ...ecommended Ferruled Unsheathed 0 25 to 1 5 mm2 Sheathed 0 25 to 0 75 mm2 Expose wire conductors by 10 mm 0 39 Stripped length 10mm CONNECTION PROCEDURE Insert the wire end until it comes to a full sto...

Отзывы: