MODEL: M2PRU

PERFORMANCE

Response time: 25 μsec. + input cycle + output cycle
(time required for the first pulse to be output from a train of
pulse input)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute  (input to output
to power to ground)

STANDARDS & APPROVALS

CE conformity:
  EMC Directive (2004/108/EC)
  EN 61000-6-4 (EMI)
  EN 61000-6-2 (EMS)
  Low Voltage Directive (2006/95/EC)
  EN 61010-1
  Installation Category II
  Pollution Degree 2
  Max. operating voltage 300V
  Input or output to power: Reinforced insulation
  Input to output
  Open collector/voltage pulse output: Basic insulation
  AC/DC switch output: Reinforced insulation
Approval:
  UL/C-UL nonincendive Class I, Division 2,
  Groups A, B, C, and D hazardous locations
  (ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
  UL/C-UL general safety requirements
  (UL 61010B-1, CAN/CSA-C22.2 No.1010-1)

EXTERNAL VIEW

Scaling Factor

Pulse Width Adj.

Pulse Width
Range Selector

*

Settings 7 through 9 are invalid.

  No pulse output with these settings.

The front cover cannot be opened to 180 deg. 
when flush with neighboring units.

■ 

FRONT VIEW (with cover open)

■ 

RIGHT SIDE VIEW

Pulse Sensing Type Selector

DC
AC

: DC coupling
: Capacitor coupling

DC
AC

(A) 10

–1

(B) 10

–2

(C) 10

–3

(D) 10

–4

(E) 10

–n

*

Refer to the instruction manual for detailed procedures.

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание M2PRU

Страница 1: ...z 90 264 V for UL DC Power R 24 V DC Operational voltage range 24 V 10 ripple 10 p p max R2 11 27 V DC Operational voltage range 11 27 V ripple 10 p p max Select N for Standards Approvals code P 110 V...

Страница 2: ...shortcircuit Open Collector Frequency range 0 100 kHz Pulse width time requirement Min 5 sec for ON and OFF Sensing Approx 24 V DC 2 mA Detecting levels 400 0 8 V for ON 1200 2 4 V for OFF Mechanical...

Страница 3: ...t Reinforced insulation Approval UL C UL nonincendive Class I Division 2 Groups A B C and D hazardous locations ANSI ISA 12 12 01 CAN CSA C22 2 No 213 UL C UL general safety requirements UL 61010B 1 C...

Страница 4: ...or Input Connection Examples PWR Voltage Pulse DC Coupled PWR Open Collector Output Connection Examples 9 12 9 12 Voltage Pulse 9 12 AC DC SWITCH SCALING FACTOR ADJ Scaler PULSE WIDTH ADJ 12k 24V 1 4...

Страница 5: ...o observe these re quirements may invalidate the CE UL conformance POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicat...

Страница 6: ...in the diagram below or refer to the connection diagram on the side of the unit OUTPUT 9 12 U V POWER 13 14 INPUT 1 5 4 SENSOR EXCITATION Mechanical Contact Open Collector Input Connection Examples PW...

Страница 7: ...switches 10 1 through 10 n apply respectively to each digit of the decimals and exponential as shown below Output Rate Input Rate 0 A B C D 10 E where the scaling factor is adjustable from 1 0000 10...

Отзывы: