TERMINAL CONNECTIONS

Connect the unit as in the diagram below or refer to the connection diagram on the top of the unit.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

5

6

7

8

2

1

11

10

80 (3.1

5)

50 (1.97)

107 (4.21)

136 (5.35)

[3.3 (.13)]

80 (3.1

5)

20 (.79)

40 (1.57)

50 (1.97)

7.8 (.31)

CLAMP

(top & bottom)

DIN RAIL

35mm wide

2

4.5 (.18) dia.

MTG HOLE

25 (.98) deep

11

M3.5

SCREW

• When mounting, no extra space is needed between units.

3

9

4

 

CONNECTION DIAGRAM

+

OUTPUT

1

2

U(+)

V(–)

POWER

7

8

PU-2x

MODULAR JACK

INPUT

+ 5

4

6

+

SENSOR EXCITATION

9

10

ALARM OUTPUT

5

4

6

+

5kΩ

■ 

Dry Contact

    or Mechanical Contact

Input Connection Examples 

+


Vsns

PWR

■ 

2-Wire Current Pulse

• Built-in Excitation

5

4

6

+

Vsns

2-WIRE

PICK-UP

• External DC Supply

5

4

6

Vsns

2-WIRE

PICK-UP

+

+

DC SUPPLY

100Ω

■ 

Voltage Pulse

5

4

6

+

+


Vsns

PWR

100Ω

JPA2

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-1572  Rev.5  P. 2 / 9

Содержание JPA2

Страница 1: ...t in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject the unit to physical impact Environ...

Страница 2: ...ng no extra space is needed between units 3 9 4 CONNECTION DIAGRAM OUTPUT 1 2 U V POWER 7 8 PU 2x MODULAR JACK INPUT 5 4 6 SENSOR EXCITATION 9 10 ALARM OUTPUT 5 4 6 5k Dry Contact or Mechanical Contac...

Страница 3: ...pulse sink detected when it goes below the level input monitor LED OFF Two Wire Current Pulse The input resistor 100 converts the current signal 0 25mA into 0 2 5V A pulse rise detected when the volt...

Страница 4: ...with Amplitude 5V p p DC Offset 2 5V Frequency Range 0 1 kHz Input type Voltage Pulse Frequency range selected 0 1 kHz Select the frequency range and set 0 and 100 range values with the Programming Un...

Страница 5: ...collector Mechanical contact Two wire current pulse 1 A specific sensitivity scale is applied according to the pulse amplitude setting The scaled input voltage is then com pared to the preset detectin...

Страница 6: ...PU 2x MODULAR JACK INPUT 5 4 6 SENSOR EXC 9 10 ALARM OUTPUT V A Ammeter Voltmeter How to Change the Excitation A voltmeter and ammeter of class 0 5 or better accuracy are required 1 Connect the voltme...

Страница 7: ...5 Frequency Range 0 FRQRNG 10mHz 0 10 mHz 1 FRQRNG 100mHz 0 100 mHz 2 FRQRNG 1 0Hz 0 1 Hz 3 FRQRNG 10Hz 0 10 Hz 4 FRQRNG 100Hz 0 100 Hz 5 FRQRNG 1 0kHz 0 1 kHz 6 FRQRNG 10kHz 0 10 kHz 7 FRQRNG 100kHz...

Страница 8: ...ed pairs of I O points Refer to the figure below X nn Input Y nn Output Range 15 00 to 115 00 15 0 Y01 X02 X03 X04 X05 115 Y02 X01 Y03 Y04 100 Y05 INPUT OUTPUT 5 GROUP 01 ITEM MDFY DATA EXAMPLE 60 61...

Страница 9: ...rding to the connection diagram 2 Power input voltage Check voltage across the terminal 7 8 with a multimeter 3 Input Check that the input signal is within 0 100 of the full scale 4 Output Check that...

Отзывы: