![background image](http://html1.mh-extra.com/html/m-system/hdms/hdms_user-manual_3122089018.webp)
Aftermarket – HDMS FMCW RADAR
PAGE - 18 -
4
RADAR Installation and Test Procedure
4.1
RADAR Test Compliance
- The installation location and installation method of RADAR are based on “
Appendix C. Test
Procedure for RADAR Sensors in ISO 16001 2017 documents”.
- RADAR's test object should be a human body part protruding to the sensing area. For testing, a real
person with the height of an intermediate pilot must use it in accordance with ISO 3411.
- The surrounding environment for the test should be an open space of flat terrain based on dry sand,
dry gravel, or a combination of dry sand and dry gravel. Everyone except the person performing the
test should be in an area not detected by RADAR
(excerpt from part of the C.3 test area of ISO 16001 2017).
4.2
RADAR Installation Compliance
- This RADAR is permanently attached or fixed to the vehicle. (If the RADAR is shaken by surrounding
environment or vibration, the basic sensing performance may be degraded.)
- Using RADAR's bracket or self-made bracket, it can be well fixed to the position where the RADAR is
mounted.
- The recommended installation height of RADAR is 1.4-1.6m, and the angle of RADAR can be adjusted
according to the installation environment. (As the angle of RADAR faces downward, the detection
range decreases, and ground effect may occur due to the ground.)