54UL

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-6488-A  Rev.2  P. 5 / 6

2S

2L

3S

3L

NC

1S

1L

P3

N

P1

P2

2

 CONFIGURATION CODE: 2

U(+) NC

DO/PO

DI+ NC FG NET1 NET1

V(   ) NC

DI

NC

FG NET2 NET2

DO/PO

+

P1 P2 P3 1S 1L 3S 3L

1

source

load

N / 2

2 / 3

u

v

v

u

U

V

V U

k

l

K

L k

l

K

L

P1 P2 P3 1S 1L 3S 3L

1

source

load

N / 2

2 / 3

k

l

K

L k

l

K

L

P1 P2 P3 1S 1L 3S 3L

1

source

load

N / 2

2 / 3

P1 P2 P3 1S 1L

1

source

load

2
3

u

v

v

u

U

V

V U

k

l

K

L

P1 P2 P3 1S 1L

1

source

load

2
3

k

l

K

L

P1 P2 P3 1S 1L

1

source

load

2
3

P1 P2

1S 1L

1

source

load

2

k

l

K

L

u

v

U

V

P1 P2

1S 1L

1

source

load

2

k

l

K

L

P1 P2

1S 1L

1

source

load

2

System / 
Application

Single-phase /
2-wire

Three-phase /
3-wire,
balanced load

Single-phase /
3-wire

Three-phase /
3-wire,
unbalanced load
(2CT)

Terminal

1S 1L

3S 3L

1

source

load

2
3

k

l

P1

u v

U V

P2

u v

U V

P3

u v

U V

N

K

L

k

l

K

L

P1

P2

P3

1S 1L

3S 3L

N

1

source

load

2
3

k

l

K

L

k

l

K

L

2S 2L

k

l

K

L

P1

P2

P3

1S 1L

3S 3L

N

2S 2L

1

source

load

2
3

N

N

N

2S 2L

k

l

K

L

1S 1L

3S 3L

1

source

load

2
3

k

l

P1

v

u

U

V

P2

u

v

U

V

P3

K

L

k

l

K

L

P1

P2

P3

1S 1L

3S 3L

1

source

load

2
3

k

l

K

L

k

l

K

L

2S 2L

k

l

K

L

P1

P2

P3

1S 1L

3S 3L

2S 2L

1

source

load

2
3

2S 2L

k

l

K

L

P1 N

1S 1L

1

source

load

2

k

l

K

L

u

v

U

V

P1 N

1S 1L

1

source

load

2
3

N

k

l

K

L

P1 N

1S 1L

1

source

load

2

3

3

N

N

System / 
Application

Three-phase /
4-wire,
balanced load

Three-phase /
3-wire,
unbalanced load
(3CT)

Three-phase /
4-wire,
unbalanced load

Terminal

Note: For low voltage circuit, grounding is not required.

Содержание 54UL

Страница 1: ...move or mount the unit turn off the power supply and input signal for safety ENVIRONMENT Indoor use Do not install the unit where it is directly exposed to rain water droplets or sunlight When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject th...

Страница 2: ...ary Power Supply Terminals Auxiliary Power Supply Terminals CONTROL BUTTON OPERATIONS IU PQS MAX E PRG ESC PF THD IU PQS PF THD Hold down IU Hold down Hold down Hold down Hold down Hold down Hold down NORMAL MODE Indicates values Indicates Voltage or Current Indicates Power Indicates Power Factor or THD Indicates totalized values max min average demand Switches Energy readings Switches to My Defau...

Страница 3: ...3 60 91 5 3 60 100 3 94 25 98 MOUNTING BRACKET 2 M5 SCREW 2 110 4 33 110 4 33 91 5 3 60 91 5 3 60 115 4 53 25 98 MOUNTING BRACKET 2 M5 SCREW 2 92 92 0 8 3 65 0 3 63 0 8 3 65 0 3 63 Panel thickness 2 to 15 08 to 59 45 1 77 45 1 77 45 1 77 45 1 77 PANEL CUTOUT unit mm inch USING MOUNTING SCREWS Remove the mounting brackets USING MOUNTING BRACKETS Remove the mounting screws Panel thickness 2 to 10 08...

Страница 4: ...P3 1S 1L 3S 3L 1 source load N 2 2 3 k l K L k l K L P1 P2 P3 1S 1L 3S 3L 1 source load N 2 2 3 P1 P2 P3 1S 1L 1 source load 2 3 u v v u U V V U k l K L P1 P2 P3 1S 1L 1 source load 2 3 k l K L P1 P2 P3 1S 1L 1 source load 2 3 P1 P2 1S 1L 1 source load 2 k l K L u v U V P1 P2 1S 1L 1 source load 2 k l K L P1 P2 1S 1L 1 source load 2 System Application Single phase 2 wire Three phase 3 wire balance...

Страница 5: ...e load 2 System Application Single phase 2 wire Three phase 3 wire balanced load Single phase 3 wire Three phase 3 wire unbalanced load 2CT Terminal 1S 1L 3S 3L 1 source load 2 3 k l P1 u v U V P2 u v U V P3 u v U V N K L k l K L P1 P2 P3 1S 1L 3S 3L N 1 source load 2 3 k l K L k l K L 2S 2L k l K L P1 P2 P3 1S 1L 3S 3L N 2S 2L 1 source load 2 3 N N N 2S 2L k l K L 1S 1L 3S 3L 1 source load 2 3 k ...

Страница 6: ...ew discrete input discrete output LONWORKS auxiliary power Torque 0 6 N m M4 Screw voltage input current input Torque 1 4 N m COMMUNICATION CABLE CONNECTION HOST PC LONWORKS 54UL LONWORKS 54UL LONWORKS Terminator CONFIGURATION VIA INFRARED COMMUNICATION Multi Power Monitor model 54UL max 1 meter Infrared Communication Adaptor model COP IRU Note 1 Hold down IU button to enter to Infrared Communicat...