COMPONENT IDENTIFICATION

IU

PQS

PF THD

MAX

E PRG ESC

2

2

 FRONT VIEW

 REAR VIEW
• Configuration Code 1

Discrete I/O 
Terminals

Infrared Interface

Voltage Input
Terminals

Current Input
Terminals

L

ON

W

ORKS

Terminals

Control Buttons

Data Displays

• Configuration Code 2

Discrete I/O 
Terminals

Current Input
Terminals

L

ON

W

ORKS

Terminals

Voltage Input
Terminals

SERVICE

Service Lamp/

Infrared Interface

Auxiliary Power 
Supply Terminals

Auxiliary Power 
Supply Terminals

■ 

CONTROL BUTTON OPERATIONS

IU

PQS

MAX

E PRG ESC

PF THD

IU

+

+

PQS

PF THD

Hold down

IU

Hold down

Hold down

Hold down

Hold down

Hold down

Hold down

NORMAL MODE
Indicates ∑ values
Indicates Voltage or Current
Indicates Power
Indicates Power Factor or THD
Indicates totalized values
(max., min., average/demand)
Switches Energy readings
Switches to My Default mode
Switches to Setting mode
Indicates nth Harmonic distortion
Switches Energy reading units
Switches to Infrared Communication mode
Indicates the shortcut menu
L

ON

W

ORK

S Service Pin

SETTING MODE
Go Left
Go Right
Go Down
Go Up

Selects menu; Enables setting changes

Cancels setting changes
----
----
----
----
----
----
----

BUTTON OPERATION

FUNCTIONS

PF THD

E PRG ESC

E PRG ESC

Содержание 54UL

Страница 1: ...move or mount the unit turn off the power supply and input signal for safety ENVIRONMENT Indoor use Do not install the unit where it is directly exposed to rain water droplets or sunlight When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ventilation Do not install the unit where it is subjected to continuous vibration Do not subject th...

Страница 2: ...ary Power Supply Terminals Auxiliary Power Supply Terminals CONTROL BUTTON OPERATIONS IU PQS MAX E PRG ESC PF THD IU PQS PF THD Hold down IU Hold down Hold down Hold down Hold down Hold down Hold down NORMAL MODE Indicates values Indicates Voltage or Current Indicates Power Indicates Power Factor or THD Indicates totalized values max min average demand Switches Energy readings Switches to My Defau...

Страница 3: ...3 60 91 5 3 60 100 3 94 25 98 MOUNTING BRACKET 2 M5 SCREW 2 110 4 33 110 4 33 91 5 3 60 91 5 3 60 115 4 53 25 98 MOUNTING BRACKET 2 M5 SCREW 2 92 92 0 8 3 65 0 3 63 0 8 3 65 0 3 63 Panel thickness 2 to 15 08 to 59 45 1 77 45 1 77 45 1 77 45 1 77 PANEL CUTOUT unit mm inch USING MOUNTING SCREWS Remove the mounting brackets USING MOUNTING BRACKETS Remove the mounting screws Panel thickness 2 to 10 08...

Страница 4: ...P3 1S 1L 3S 3L 1 source load N 2 2 3 k l K L k l K L P1 P2 P3 1S 1L 3S 3L 1 source load N 2 2 3 P1 P2 P3 1S 1L 1 source load 2 3 u v v u U V V U k l K L P1 P2 P3 1S 1L 1 source load 2 3 k l K L P1 P2 P3 1S 1L 1 source load 2 3 P1 P2 1S 1L 1 source load 2 k l K L u v U V P1 P2 1S 1L 1 source load 2 k l K L P1 P2 1S 1L 1 source load 2 System Application Single phase 2 wire Three phase 3 wire balance...

Страница 5: ...e load 2 System Application Single phase 2 wire Three phase 3 wire balanced load Single phase 3 wire Three phase 3 wire unbalanced load 2CT Terminal 1S 1L 3S 3L 1 source load 2 3 k l P1 u v U V P2 u v U V P3 u v U V N K L k l K L P1 P2 P3 1S 1L 3S 3L N 1 source load 2 3 k l K L k l K L 2S 2L k l K L P1 P2 P3 1S 1L 3S 3L N 2S 2L 1 source load 2 3 N N N 2S 2L k l K L 1S 1L 3S 3L 1 source load 2 3 k ...

Страница 6: ...ew discrete input discrete output LONWORKS auxiliary power Torque 0 6 N m M4 Screw voltage input current input Torque 1 4 N m COMMUNICATION CABLE CONNECTION HOST PC LONWORKS 54UL LONWORKS 54UL LONWORKS Terminator CONFIGURATION VIA INFRARED COMMUNICATION Multi Power Monitor model 54UL max 1 meter Infrared Communication Adaptor model COP IRU Note 1 Hold down IU button to enter to Infrared Communicat...

Отзывы: