manualshive.com logo in svg
background image

47LV

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: [email protected]

EM-9502-A  Rev.6  P. 4 / 5

 

CONNECTION DIAGRAM

1

9

10

POWER

U(+)

V(–)

17

15

16

 ALARM OUTPUT CODE 1: N.O. contact, 4 points

20

18

19

1

2

3

4

9

10

INPUT

POWER

U(+)

Lc (COM)

Lb (NC)

La (NO)

Hc (COM)

Hb (NC)

Ha (NO)

V(–)

17

15

16

 ALARM OUTPUT CODE 2: SPDT contact, 2 points

20

18

19

Lc, LLc

LLa

La

Hc, HHc

Ha

HHa

2

3

4

INPUT

LL OUTPUT

L OUTPUT

H OUTPUT

L OUTPUT

H OUTPUT

HH OUTPUT

1

9

10

POWER

U(+)

V(–)

 ALARM OUTPUT CODE 0: No alarm output

2

3

4

INPUT

DC OUTPUT

7

8

+

DC OUTPUT

7

8

+

DC OUTPUT

7

8

+

LOAD

Inductive

Load (Coil)

Varistor or

CR Circuit

• DC Powere

d

LOAD

Inductive

Load (Coil)

Diode, Varistor

or CR Circuit

 Relay Protection

• AC Powere

d

Note:  The section enclosed by broken line is only with DC output option.

+

+

+

V1

V2

I

COM –

1

3

2

4

+

+

V

I

COM –

1

3

2

4

+

1

3

2

4

+ 1

3

2

4

• Input code:

 1, 2

                

• Input code:

 3

                    

• Input code: 

4

        

• Input code : 

 5, 6

  

U

• Input Terminal Assignments

INPUT TYPE 

MEASURING

INPUT

(indicator)

 RANGE 

TERMINALS

V200

±200V

1  –  4

V10

 ±10V

 

V5

    ±5V

 

V1

±1V

V01 

  ±100mV

2  –  4

V001

    ±10mV

INPUT TYPE 

MEASURING

INPUT

(indicator)

 RANGE 

TERMINALS

V0-5

0 – 5V 

2  –  4

V1-5

1 – 5V

A100 

±100mA

3  –  4

 

A1

    ±1mA

A0-2

0 – 20mA

A4-2

4 – 20mA

   A2-2                     ±2A

   A1-1                     ±1A

  V700                   ±700V

 A01                     ±100μA 

 

TERMINAL BLOCK

• 

How to remove the terminal cover

Insert the minus tip of a screwdriver into each hole at the  
four corners of the cover and pull it to the direction as 
indicated below to separate the terminal cover.

Terminal Cover

• 

How to remove the terminal block

The terminal block is separable in two pieces.  Loosen two 
screws on both sides of the terminal block to separate.
Be sure to turn off the power supply, input signal and 
power supply to the output relays before separating the 
terminal block.

Separable

Terminal Block

Terminal Block

Screw