m-sur
e.co
.uk
www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.
M-SURE Digital Depth Gaug
es
Referencing Standard Depth Gauge
Referencing Depth Gauge with hook
1. Ensure the locking screw is loose.
2. Wipe clean surface plate or similar flat
service.
3. Ensure Gauge base is clean.
4. Place Gauge base on the surface plate.
5. Slide the beam downwards so
measuring contact is in contact with the
surface plate.
6. Press the zero button.
1. Ensure the locking screw is loose.
2. Ensure the Gauge base and hook is
clean.
3. Close the Gauge.
4. Press the zero button.
Metric/Inch Conversion
25.40
mm
in/mm
Press in/mm to convert from
inch to metric display.
1.000
The display will indicate
which units are being
displayed.
in/mm
in
Trouble Shooting
Problem
Possible Cause
Solution
Flashing display
Low voltage
Poor contact
Replace battery
Clean contact
No display
Dead or weak battery
Poor contact
Replace battery
Clean contact
Erratic or frozen display
Contamination between beam & head
low voltage
Wipe Depth Gauge clean
Replace battery
Erroneous reading
Low voltage
Contamination between beam & head
Too much operating force
Low ambient temperature
Replace battery
Wipe Depth Gauge clean
Use pressure device
Store Depth Gauge at normal room
temperature