ISM0210 Instruction Manual of series SCE- Rev.03
Pag. 17/33
Fire-fighting equipment to be used:
In case of fire involving the pump, you can use water or foam liquid only after removing the voltage, or a powder
type fire extinguisher with extinguishing agent. Do not use CO2 as being launched at -79 ° C may react violently
with the hot parts.
Emission / dispersion of harmful substances
The fluid in the plant might be released in the atmosphere following an intervention or the pump break.
MALFUNCTIONING, FAILURE, BREAKDOWN, ACCIDENT. MOST FREQUENT
PROBLEMS: CAUSES AND REMEDIES
There aren’t pump details which provide such cases of malfunctioning as to restrict or make its use dangerous.
In paragraph “Most frequent drawbacks: causes and remedy” is discussed with more details in this section.
Malfunctioning and Failure
In case of failure of mechanical parts you must immediately restore the original terms of security by replacing or
repairing the parts that have deficiencies.
In case of failure of the pump, proceed as follows:
-
Turn the motor off;
-
close the inlet and outlet valves;
-
find the cause of the failure by checking the section “ Most frequent drawbacks: problems, causes,
remedies, residual risks".
The failure of a pumping plant can be attributed to:
- a pump failure;
-
a failure or defect in the pipe;
−
a failure due to an installation or a start not correctly executed;
−
wrong choice of pump.
Breakdown
In the event of failure of pump alert verbally the staff present in the nearness of the damage that is verifying.
Accident
In case of accident, you must report the emergency to the plant responsible for the installation, in order to
secure the plant to reach with the emergency team the place where the accident happened
.
Most frequent drawbacks: problems, causes, remedies, residual risks
INSUFFICIENT FLOWS
Causes
Remedies / actions to be taken
The head requested exceeds the pump head
expected.
Increase the speed rotation if possible.
Mount an impeller of greater diameter
Reduce the total head of the system if possible.
Increase the diameter of the discharge pipe.
Check that the discharge valve is fully open.
Replace the pump.
Ask your
M PUMPS PROCESS
distributor.
The pump rotates in the opposite direction.
Check the direction of rotation.
Refer to section 3.5 of this manual
Air or steam trapped in the suction
.
Check the presence of air or steam trapped. Refer to section
3.4 of this manual.
Содержание SCE Series
Страница 10: ...Pag 10 33 ISM0210 Instruction Manual of series SCE Rev 03 3...
Страница 25: ...ISM0210 Instruction Manual of series SCE Rev 03 Pag 25 33 EXPLODED VIEW PART LIST Close coupled version...
Страница 26: ...Pag 26 33 ISM0210 Instruction Manual of series SCE Rev 03...
Страница 27: ...ISM0210 Instruction Manual of series SCE Rev 03 Pag 27 33 NOTES...