background image

5

www.m-locks.com

Rotobolt

V03

EN

BOLTWORK REQUIREMENTS

The force applied to the boltwork on the lock bolt has to be limited to 1 kN (p. E. by a preconceived 
breaking point). Please contact your manufacturer if higher forces are needed. Only use supplied 
screws to mount the lock.

The maximum allowed cable/spindle-hole diameter is 11mm (if located 
under the lock body)
If the Rotobolt lock is used in conjunction with another lock, the boltwork 
must be constructed in a way that the Rotobolt secures first.

In the LOCKED position the distance between the Rotobolt bolt and the bolt-
work part that is moving the lock bolt should be approximately 1 mm. 

Only use supplied screws to mount the lock. Tighten the screws securely so 
the lock body is attached firmly to the mounting surface.
(Maximum Torx 5, 5 Nm)

  

 

MOUNTING INSTRUCTIONS

Mount the entry unit following the manufacturer’s instruction.

Insert the connector of the entry unit in the 
outer (ENT) position.  Connect battery / alarm 
box connector (if used) in the inner (BAT) 
position. Check that the connector(s) is com-
pletely seated.  

To remove the connector(s), carefully lift and 
pull it out.

Connect a 9V alkaline Duracell , Energizer or Duracell Industrial battery to the battery clip to  the 
keyboard (or battery box) , and check the lock functions . Keep the cable from sharp edges or moving 
boltwork parts and set permanently .

Содержание Rotobolt EM2020

Страница 1: ...Rotobolt EM2020 EM2050 M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com Mounting instructions V03 EN ...

Страница 2: ...2 www m locks com EM2020 EM2050 ...

Страница 3: ... we are asking you to touch the metal surface of the safe for discharging before operating the lock Caution The lock has been designed for use in a temperature range from 10 C to 50 C and a non condensing humidity range from 30 to 80 It may only be cleaned with a moist cloth do not use aggressive cleaning agents The lock may only be installed by qualified fitters The lock may not be lubricated Nev...

Страница 4: ...er is 11mm if located under the lock body Position of the cable hole depends on which entry unit is used The lock has to be fitted exclusively on steel secure storage The mounting base also must be made of steel Installation on other materials only after consultation M LOCKS or VdS It is recommended to prevent access to unauthorized persons to safety relevant parts of the high security lock when t...

Страница 5: ... work part that is moving the lock bolt should be approximately 1 mm Only use supplied screws to mount the lock Tighten the screws securely so the lock body is attached firmly to the mounting surface Maximum Torx 5 5 Nm 5 MOUNTING INSTRUCTIONS Mount the entry unit following the manufacturer s instruction Insert the connector of the entry unit in the outer ENT position Connect battery alarm box con...

Страница 6: ...ing the safe door Check the keypad If the lock does not react follow the procedure below to check that your keypad is working Press and hold key 5 until you hear a double tone The LED will illuminate when performing the fol lowing actions 5 Next press all of the keys in one by one and one after the other 1 2 3 4 5 6 7 8 9 0 If the key OK If the key not OK the test will be aborted If one or more ke...

Страница 7: ...ISCH EM2020 EM2020 S EM2050 EM2050 S EM2050 AB Power supply 9V Alkaline Duracell Duracell Industrial or other oder Energizer block batteries Codes 2 6 digits Up to 10 6 or 7 digits Up to 10 6 or 7 digits Manager Codes 1 1 1 User Codes 1 Up to 9 Up to 9 Time delay open window 01 99 min 01 19 min 01 99 min 1 19 min 01 99 min 1 19 min Battery low signal Yes Yes Yes Dallas key and code Dallas key and ...

Страница 8: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com ...

Отзывы: