5
www.m-locks.com
Motor lock
V01
EN
4
BOLT REQUIREMENTS AND LOCK MOUNTING
The force applied to the lock bolt in locked condition must not exceed 1 KN (p. E. by a preconceived
breaking point). If higher force is desired please consult with the manufacturer. Only use supplied
screws to mount the lock. Handtighten the screws securely so the lock body is attached firmly to the
mounting surface.
In the LOCKED position, there should be approximately 1 mm clearance
between the lock bolt and the cavity in the blocking bar of the bolt-
work. The lock bolt must move freely into the cavity.
Any bolt attachment should not exceed 0.5 Kg / 1 lb.
(equals a force of 5N)
When the lock bolt is retracted, the distance to the blocking bar must
not exceed 5 mm.
5
MOUNTING INSTRUCTIONS
Insert the connector of the entry unit in the inner position. Check that the connector(s) is completely
seated. To remove the connector(s), carefully lift and pull it out. In the entry unit or battery / alarmbox
connect a 9V ALKALINE Duracell, Industrial or Energizer batteries. Tie cables away from moving parts.
Note:
If a cable /spindle hole is located under the Motor lock, use a suitable drill protection; part number
T016.
Cable-hole 9-12 mm.