background image

5

www.m-locks.com

Motor lock

V01

EN

BOLT REQUIREMENTS AND LOCK MOUNTING

The force applied to the lock bolt in locked condition must not exceed 1 KN (p. E. by a preconceived 

breaking point). If higher force is desired please consult with the manufacturer. Only use supplied 

screws to mount the lock. Handtighten the screws securely so the lock body is attached firmly to the 

mounting surface.

 

   

In the LOCKED position, there should be approximately 1 mm clearance

 

   

between the lock bolt and the cavity in the blocking bar of the bolt- 

 

   

work. The lock bolt must move freely into the cavity.

 

   

 

   

Any bolt attachment should not exceed 0.5 Kg / 1 lb.

 

   

(equals a force of 5N)

 

 

 

 

When the lock bolt is retracted, the distance to the blocking bar must  

 

 

not exceed 5 mm.

MOUNTING INSTRUCTIONS

Insert the connector of the entry unit in the inner position. Check that the connector(s) is completely 

seated. To remove the connector(s), carefully lift and pull it out. In the entry unit or battery / alarmbox 

connect a 9V ALKALINE Duracell, Industrial or Energizer batteries. Tie cables away from moving parts.

Note:

If a cable /spindle hole is located under the Motor lock, use a suitable drill protection; part number 

T016.

Cable-hole 9-12 mm.

Отзывы: