background image

Instructions for installation and use TRUE VISION 1000-1300RD Gas

V E R Y   I M P O R T A N T

I N S T A L L A T I O N   I N S T R U C T I O N S 

F O R   T H E   M - D E S I G N G   G A S 

F I R E P L A C E S

T H E   S U P P L I E R   T A K E S   N O   R E S P O N S B I L I T Y   F O R   A N Y 

P O S S I B L E   D A M A G E ,   P O O R   W O R K I N G A P P L I A N C E S   A N D 

A C C I D E N T   A S   A   R E S U L T   O F   I N C O R R E C T 

I N S T A L L A T I O N

MAINTENANCE GAS FIREPLACE M-DESIGN

THE M-DESIGN GAS FIREPLACES MUST BE CHECKED EVERY 

2 YEARS AND GET A 

MAINTENANCE. THIS IS ALSO TO MAINTAIN YOUR 

WARRANTY. IF THIS WILL BE NOT 

OBSERVED, THE WARRANTY FELL.

YOU CAN RELY ON M-DESIGN TO MAKE THIS CHECK FOR 

YOU, OR YOU CAN DO THIS BY YOURSELF AND FOLLOW 

THE METHOD BELOW.

Содержание True Vision 1000 RD

Страница 1: ...12 2019 TRUE ISION 1000 1300 RD INSTRUCTIONS FOR INSTALLATION AND USE Distributor Manufacturer M Design Benelux BVBA B 8210 Zedelgem Belgium ...

Страница 2: ... P O S S I B L E D A M A G E P O O R W O R K I N G A P P L I A N C E S A N D A C C I D E N T A S A R E S U LT O F I N C O R R E C T I N S TA L L AT I O N MAINTENANCE GAS FIREPLACE M DESIGN THE M DESIGN GAS FIREPLACES MUST BE CHECKED EVERY 2 YEARS AND GET A MAINTENANCE THIS IS ALSO TO MAINTAIN YOUR WARRANTY IF THIS WILL BE NOT OBSERVED THE WARRANTY FELL YOU CAN RELY ON M DESIGN TO MAKE THIS CHECK F...

Страница 3: ...2 Nearbox Gasunit 7 3 1 3 The Gas connection 8 3 1 4 Electrical connection 9 3 1 5 Modification natural gaz to propane 9 4 INSTALLING THE CHIMNEY 10 13 5 FLAME ADJUSTMENT SETTINGS 14 6 INSULATION AND FINISHING 14 7 CONVECTION CURRENT 15 16 8 POSITIONING THE LOGS 17 20 9 FIRST TIME USE 21 10 SAFETY ADVICE AND MAINTENANCE 21 11 GUARANTEE 22 12 REMOTE CONTROL 23 25 13 DRAWINGS 26 ...

Страница 4: ...nce action that may be performed on the device by the user Thanks to a patented system the door can be easily opened at an angle of 45 to allow a user friendly cleaning of the window To close push the door gently but not to soft against the hooks Make sure that all hooks are hooked CLOSING OPEN Above the glass below the upper frame hooks are provided left right and center Push it upwards with your...

Страница 5: ...rder specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the ap pliance please check the local regulations about this type of appliance identification of the type of gas etc and check that the furnace is adapted to your means of installationt It is imperative that the installer sees to the following...

Страница 6: ... to be installed with a different height unscrew the nut to remove the feet Grind the desired height on foot The distance between two holes is 40mm With the fireplace is provided 4 small saucers Use to get the stud under your feet If you want to install the fireplace at the minimum height of 25mm measured from the floor to Below the firebox remove the foot and unscrew the nut below the foot Aim th...

Страница 7: ... gasbattery or NEARBOX is fixed with screws on the pallet Unscrew and remove the gasunit before installation gas connection1 2 reciever DFGT 03MC01 V09 Transmitter burner Gas valva VK4105ME5004 3 1 2 Nearbox gasunit gas connection1 2 to main burner Electro magnet ventil 1 or 2 burners NEARBOX FOR 1 BURNER NEARBOX FOR 2 BURNERS to main burner 455 2 burners to second burner or side burner ...

Страница 8: ...om the of the back of the fire you can place it loosely on the ground in proximity to the opening provided in the wall of mantelpiece The device is always connected with an approved gas tap 1 2 and preferably with a yellow gasflexible that is reachable at all times Provide the mantelpiece with a door so that the valve and the electrical connection is easily accessible GAS SUPPLY TO SIDE BURNER OR ...

Страница 9: ...king an earthened 220V socket necessary You should bear in mind that the appliance must be connected to all electrical supplies for the purposes of service It s obligatory to connect an earth current 3 1 5 Modification natural gaz to propane Modification of the fireplace can only be done by the manufacturer or an approved installer A new signal plate is provided ...

Страница 10: ...OP METALOTERM tested our appliances with their conduct and we only guarantee a good working of the appliance with those Between the external wall of the pipe and the wall or the ceiling you should allow for a clearance of at least 50mm and protection that is suitable against temperatures of around 130 C The passage of the front panel cowl in the external wall must be filled in using silicone masti...

Страница 11: ...s 4 2 ROOF EXIT VIA EXISTING CHIMNEY C91S flex 130mm This USSAN piece must be sealed at the roof Ø200 Ø 130 Appliance C min C max Restriction as from 4m True Vision 1000 RD 2 m 10m Ø 60 True Vision 1300 RD 2 m 10m Ø 60 This USSAN piece must be sealed at the top of the chemney ...

Страница 12: ...es not have a negative in clination in direction of the outlet It is even better when possible to have a little inclination of 2 or 3 degrees ascending to avoid rain and condenstation in the tube Install wall outlet like fig 1 Ø 200 130 Appliance A min B min B max True Vision 1000 RD 1m Wall Exit A True Vision 1300 RD 1m Wall Exit Wall Exit ...

Страница 13: ...0 RD for each 90 bend subtract 1m horizontally or add 1m vertically 1000 1300 RD for each 45 30 15 bend subtract 0 5m horizontally or add 0 5 m vertically Picture 4 ROOF EXIT WITH BEND Ø 200 130 Appliance A min B max C min A B C max True Vision 1000 RD 1 m A C B A 12m True Vision 1300 RD 1 m A C 1m B A 81 10m ...

Страница 14: ...al gas is first burning by blue colour and it will turn yellow in time LPG burning become quicker yellow If the flame is blue it can mean that there is too much air in the combustion chamber but also that there is too little air If there is too much air the flame move very quickly Attention burner have to burn continuously evenly in the whole length included secondary burners By adjusting the flam...

Страница 15: ...rovided M Design has developed hot air and ambient air outlet grilles available from your dealer Outlet grids have two or four hose connections 2 4 hoses on 1 grid The air inlet grilles not to be connected with a hose must be placed as low as possible at the bottom of the fireplace Please follow this instructions The appliance can overheat if you not apply those instructions Errorcode F02 will app...

Страница 16: ... 102 250 2 dm 16 Instructions for installation and use TRUE VISION 1000 1300RD Gas OUTLET CONVECTION INLET CONVECTION OUTLET CONVENTION INLET CONVECTION Picture 3 Design Grill Outlet with 2 connections INLET grill covection air INLET grill covection air Design Grill outlet with 4 connections OR OR Design Grill outlet with 2 connections ...

Страница 17: ... ignition with opened window When the fire burns evenly over the entire length of burners included secondary burners the door can be closed Repeat ignition one more time with closed window x1 x2 x2 x2 x2 x3 x2 x2 Insert the secondary burners into the wood logs holes First put the imitation coal pieces Packaging 8 small bags size 15x22cm or 2 big bags size 35x25cm Warning DO NOT PUT THE DUST FROM T...

Страница 18: ...ions for installation and use TRUE VISION 1000 1300RD Gas 4 Opposite side 5 Opposite side 6 Opposite side 7 Opposite side 8 Opposite side 4 Line in wood 4 Line in wood 2 5 6 Line in wood 6 7 7 4 8 Line in wood 8 8 ...

Страница 19: ...structions for installation and use TRUE VISION 1000 1300RD Gas 9 Opposite side 10 11 12 visible only from the opposite side 13 Opposite side 14 xx Opposite side 9 11 12 10 13 14 13 Wood 14 behind the wood 4 ...

Страница 20: ...RUE VISION 1000 1300RD Gas 20 15 Opposite side 16 In the case you ordered angel s hair arrange them on the burner first then imitation coal and continue according wood manual DO NOT PUT ANYTHING ON THE IGNITION ELECTRODE 17A 17B 15 16 15 16 ...

Страница 21: ...ler 10 Safety device and maintenance Have your appliance inspected every 2 years by a qualified technician Please observe the following points Closed appliances produce intense heat which means that all the surfaces of the external walls metal door frames and windows become very hot once a certain tempera ture is reached Make sure that young children do not touch the window this could result in se...

Страница 22: ...onsequence of Non respect of the order installation and maintenance instructions Assembly installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the appliance without our consent In cases where the buyer cannot show his her warranty card with the purchase invoice Likewise where the guarantee and or the inv...

Страница 23: ...cking The ticking lasts for about 15 sec At initial setup it s possible that the pilot flame doesn t ignite imidiatly because the pipes are not yet fully deflated You can try this up to 5 times before the unit will be placed in safety If this fails pleas contact your installer 12 Remote control direct ingnition 3 Manual control From the moment the burner 1 is on you can start with the flame height...

Страница 24: ...manual control do the smame until and are blinking Confirm with 4 Thermostatic control To light up the side burners 2 press First you see the wave settings page 30 or Press a second time and you will see a b0 or b0 If b0 appears press to b1 side burners 2 lights up If b1 appaers press to b0 side burners 2 will go out Choose a flame height from 1 to 15 by pressing or To switch off the entire stove ...

Страница 25: ...WAVE 25 Instructions for installation and use TRUE VISION 1000 1300RD Gas Symbol that indicates that WAVE is enabled Press 1x short on the menu button and 1 appears Wave aan Press the arrow up or down 0 appears Wave off confirm Press to turn off the fireplace The fireplace will start up with 1 or multiple burners depending on the b position Shut down fire Switch off WAVE ...

Страница 26: ...9 5 509 int True Vision 1300RD Type 2 30mm ver 21 5 2019 520 260 Ø200 130 41 1016 162 25 5 468 509 int 221 5 259 5 510 1360 min 35 max 450 26 990 4 5 478 1204 255 5 3 517 ext 217 5 30 580 1274 125 263 300 300 1294 76 Ø150 1370 True Vision 1000RD example frame Type 2 30mm True Vision 1300RD example frame Type 2 30mm Instructions for installation and use TRUE VISION 1000 1300RD Gas 13 DRAWINGS ...

Отзывы: