10
C
C
4.1. ROOF EXIT (C31)
4. Installing the chimney
Install the concentric flue duct as indicated by ONTOP - METALOTERM. The only authorised pipes are ONTOP
Metaloterm™. ONTOP-METALOTERM tested our appliances with their conduct and we only guarantee a good
working of the appliance with those. Between the external wall of the pipe and the wall or the ceiling, you
should allow for a clearance of at least 50mm and protection that is suitable against temperatures of around
130°C. The passage of the front panel cowl in the external wall must be filled in using silicone mastic.
Ø 200/130
Ø 200/130
Appliance
C (min)
C (max)
Restriction (as from 4m)
700 / 1000 H
2 m
10m
Ø 60 (as from 2m : Ø 75)
1150 H
2 m
10m
Ø 60 (as from 2m : Ø 75)
1300 H
2 m
10m
Ø 60 (as from 2m : Ø 75)
1600 H / 1900 H
2 m
12m
Ø 60 (as from 2m : Ø 75)
Ø 150/100
Ø 150/100
Appliance
C (min)
C (max)
Resctriction (as from 4m)
700H / 1000 H
3 m
18m
Ø 60 (as from 2m : Ø 75)
1150 H
3 m
18m
Ø 53
1300 H
3 m
18m
Ø 60
1600 H / 1900 H
3 m
20m
Ø 75
This is recommended with a roof exit ≥ 3m
This is recommanded with a roof exit ≤ 3 m
Содержание Luna Diamond Series
Страница 1: ...LUNA DIAMOND GAS 700 1000 1150 1300 1600 1900H 02 2019 INSTRUCTIONS FOR INSTALLATION AND USE...
Страница 20: ...20 1 5 6 7 8 9 2 3 4 Luna 1150H Gas Luna 1150H Gas...
Страница 21: ...21 1 11 2 12 3 10 4 9 5 8 7 6 1 2 3 4 5 6 7 8 9 10 11 12 Luna 1300H Gas...
Страница 22: ...22 1 2 3 4 5 6 7 8 9 10 11 12 13 1 4 5 6 11 12 13 9 10 8 2 3 7 Luna 1600H Gas...
Страница 23: ...23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Luna 1900H Gas...
Страница 35: ...35 15 Identification boards...