Tr
o
u
b
le
sh
o
o
ti
n
g
5.10
P1(Over voltage or too low voltage protection diagnosis and solution)
Description:
Abnormal increases or decreases in voltage are detected by checking the specified voltage detection circuit.
Recommended parts to prepare:
• Power supply issues
• System leakage or blockage
• Faulty PCB
Troubleshooting and repair:
Check the power supply.
Is
it in working
order?
NO
Turn off the
unit.
YES
Check the connections and wires
.
Are they in working
order?
NO
Ensure
proper connections
or
replace the wires
.
YES
Power on and measure
the
voltage between
P
and N.
While the unit is in standby
,
is the voltage between
P
and N is
around
DC 310V, 340V or 380V? When start
up
the unit, is it in
220V~400V?
NO
Replace
the IPM
board.
YES
Check the
reactor.
Is
it in working
order?
NO
Replace
outdoor PCB.
YES
Replace
the
reactor.