background image

     

|

     5

KeyRIg 49 User Guide

Installation and Setup

The KeyRig 49 USB keyboard is class-compliant  This means that you may simply connect the provided USB cable between KeyRig 
49 and your Windows XP or Mac OS X computer and switch the keyboard on  Additional drivers are not mandatory for normal 
operation  

As you become more familiar with KeyRig 49, you may wish to take advantage of this product’s professional features such as: using 

your new keyboard with more than one application at the same time (multi-client) or sending advanced MIDI messages using KeyRig 
49’s Edit mode. When using Windows, some of these features can only be accessed after installing the optional KeyRig 49 drivers. 
No drivers are required for Mac OS X. The optional PC drivers are found on the KeyRig 49 CD-ROM included with this package.

PLEASE NOTE:

 If you are installing the optional drivers for KeyRig, disconnect your KeyRig until you are instructed to 

connect it. 

To install the optional Windows XP drivers for KeyRig 49:

 

1.   Insert the KeyRig 49 CD-ROM into your computer’s CD-ROM drive.

 

2.     The computer will automatically display the interactive install screen. If your computer fails to launch the installer, 

manually start it by clicking on Start > My Computer > KeyRig 49 

 

3.    Choose KeyRig 49 keyboard from the pull down menu and click “Install.”  

 

4    Follow the driver installer’s on-screen direction prompts  

 

5      At various points in this installation process, you may be notified that the driver being installed has not passed 

Windows Logo Testing. Click “Continue Anyway” to proceed with installation.

 

6.   Click “Finish” once the installer has completed the installation.

 

7    Connect your KeyRig 49 to an available USB port using the cable provided  

 

8.   Make sure that the power switch on the back of the keyboard is in the “on” ( I ) position.

 

9.   You will be asked if you want to search the Internet for a driver. Select “No, not this time” and click “Next.” 

 

10   Windows will display a Found New Hardware Wizard 

 

11.  Choose “Install the software automatically,” and click Next.

 

12.  Follow the on-screen direction prompts and click “Finish” when the Found New Hardware Wizard has completed.

Содержание KEYRIG KeyRig 49

Страница 1: ...User Guide Easy to Use 49 Note USB Keyboard...

Страница 2: ...on and Setup 5 Getting Started With Music Creation Software 6 The KeyRig 49 Keyboard 7 Key Names 7 Octave Buttons 7 Pitch Bend Wheel 7 Modulation Wheel 8 Volume Slider 8 Sustain Pedal Jack 8 Advanced...

Страница 3: ...leshooting Features 18 All Notes Off 18 Reset All Controllers 18 Warranty Terms and Registration 18 Warranty Terms 18 Warranty Registration 18 Technical Info 19 Appendices Useful MIDI Data 20 Appendix...

Страница 4: ...49 Keyboard Features 2 Keyboard 49 key velocity sensitive keyboard Pitch Bend wheel Modulation wheel MIDI re assignable Volume slider MIDI re assignable Octave up down buttons MIDI re assignable Edit...

Страница 5: ...ntium 3 800 MHz or higher CPU may be higher for laptops 256 MB RAM DirectX 9 0b or higher Windows XP SP2 or higher Windows 98 Me NT or 2000 not supported One native USB port Mac OS Macintosh G3 800 G4...

Страница 6: ...al Windows XP drivers for KeyRig 49 1 Insert the KeyRig 49 CD ROM into your computer s CD ROM drive 2 The computer will automatically display the interactive install screen If your computer fails to l...

Страница 7: ...music applications this entails going into the Options or Device Set Up menu in your music software application and selecting the appropriate MIDI input device KeyRig 49 should appear under the name...

Страница 8: ...shift set to zero the lights above both the Octave and Octave buttons will be lit The default octave shift designation is zero and will be the octave setting each time you power up the keyboard If you...

Страница 9: ...ent parameters such as pan balance attack reverb and chorus See chapter Advanced KeyRig 49 Features in Edit Mode for more information on this Some software applications respond to volume control MIDI...

Страница 10: ...r ENTER key is pressed The light above the Edit Mode button will then turn off and the keyboard can then be used to play notes again Some functions do not require any additional data entry When these...

Страница 11: ...s the black key above F2 F 2 In Edit mode this key functions as OCTAVE shifting the keyboard down one octave It is possible to shift the keyboard down a total of three octaves 4 Press the black key ab...

Страница 12: ...KeyRig 49 keyboard to control MIDI sound modules or synthesizers Some music software applications support these messages however others do not Check your software s User Guide to find out if it can p...

Страница 13: ...ed to change Bank LSB or Bank MSB 2 Using the Quick Select Method 1 Press the Edit Mode button 2 Press the black key above G4 G 4 or Bb4 A 4 representing Bank LSB or Bank MSB respectively 3 Press the...

Страница 14: ...Some useful MIDI CC s are 01 Modulation 07 Volume 10 Pan balance 05 Portamento To assign a MIDI controller message to the Modulation wheel 1 Press the Edit Mode button 2 Press the black key above C4...

Страница 15: ...er of the controller value you want to assign to the Volume slider 4 Press the ENTER key C5 If you make an error while entering the numerical data value you can press the CANCEL key C1 to exit Edit mo...

Страница 16: ...r layer of banks was added The result is a system of 128 banks that can contain 128 sub banks in each of them which in turn can contain 128 sounds programs within them Bank change messages are useful...

Страница 17: ...ules in Propellerhead Reason are non GM devices You can send program change bank LSB and bank MSB messages directly from the KeyRig keyboard Please consult the Advanced KeyRig 49 Features in Edit Mode...

Страница 18: ...you want the sustain pedal to be off when it is not pressed make sure the pedal is not pressed when you power up Also check to see if there is a polarity switch on your foot pedal It is possible to u...

Страница 19: ...oller to adjust to eliminate the effect you can send a Reset All Controllers MIDI message to set all controller values to their defaults To send a Reset All Controllers message 1 Press the Edit Mode b...

Страница 20: ...es cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of t...

Страница 21: ...llo 43 Contrabass 44 Tremolo Strings 45 Pizzicato Strings 46 Orchestral Harp 47 Timpani Ensemble 48 String Ensemble 1 49 String Ensemble 2 Slow 50 Syn Strings 1 51 Syn Strings 2 52 Choir Aahs 53 Voice...

Страница 22: ...ntroller 60 61 Controller 61 62 Controller 62 63 Controller 63 64 Sustain Pedal 65 Portamento 66 Sostenuto 67 Soft Pedal 68 Legato Pedal 69 Hold 2 70 Sound Variation 71 Resonance 72 Release Time 73 At...

Страница 23: ...nding a MIDI CC message You can assign these to the controls on your KeyRig 49 keyboard in exactly the same way as any other MIDI controller message The RPN messages control the following Controller N...

Страница 24: ...C 0 820 391 191 Assistance Technique e mail support m audio fr mac m audio fr fax 33 0 1 72 72 90 52 Site Web www m audio fr M Audio Germany Kuhallmand 34 D 74613 Ohringen Germany Technical Support e...

Отзывы: