20
3.5.2 Drum Pattern Composition
When you first turn your Axiom on, you will find that the pressure pads are set up as drum triggers for composing drum loops in MIDI
sequencers.
To set up the drum triggers, you need to program the pads to send specific MIDI note numbers (see previous section). The note numbers you
assign depend on the drums that you want to control. Please refer to Appendix B to see which drums are mapped to which MIDI note numbers.
Then, using the Data 1 parameter for each pad on your Axiom, assign that note number to the pad, as described above.
3.5.3 Sample/Loop Triggers With MIDI Controller Messages
Some software may require you to send standard MIDI controller messages to trigger samples or loops. To make this work you first assign a
MIDI controller to the pad and then set the pad to send just ON and OFF values. This is done as follows:
49 and 61 note versions:
<
Select the pad as described in Section 2.
<
Press the Ctrl Assign button.
<
The LCD display will flash the currently assigned controller to the pad.
<
Enter ‘146’, which sets the pad to send an ON value when pressed, and OFF value when released.
<
Press the Data 1 button and enter the controller number from Appendix C that you want the pad to send. The range of values here
is 0-127.
<
Press the Data 3 button and enter the ON value (this should be 127 in most cases).
<
Press the Data 2 button and enter the OFF value (this should be 0 in most cases).
3.5.4 Pressure Control
Using the pressure control, the pads give you a different type of performance option on your Axiom. You can control parameters on your
software in a way that would not be possible on a standard dial or slider. The pressure pads can be used to make some very interesting
effects.
As we’ve seen above, each pad can be assigned an individual MIDI controller number. It is also possible to assign minimum and maximum
values to the controller. As you apply more and more pressure to the pad, the value of the controller you are sending will increase, until the
maximum value you specified is reached. On release, the pad will return to the minimum value you specified.
To set the controller for a pressure pad, with a minimum and maximum value:
49 and 61 note versions:
<
Select the pad as described in Section 2.
<
Press the Ctrl Assign button.
<
The LCD display will flash the currently assigned controller to the pad.
<
Enter the controller number from Appendix C that you want the pad to send.
<
If you want to specify a minimum value limit, press the Data 2 button and enter the minimum value.
<
If you want to specify a maximum value limit, press the Data 3 button and enter the maximum value.
25 note version:
<
Select the pad as described in Section 2.
<
Press the Advanced button.
<
Press the Ctrl Assign key.
<
The LCD display will flash the currently assigned controller to the pad.
<
Enter the controller number from Appendix C that you want the pad to send, using the numeric data entry keys.
<
If you want to specify a minimum value limit, press the Data 2 key and enter the minimum value.
<
If you want to specify a maximum value limit, press the Data 3 key and enter the maximum value.
Section 3: Advanced Features
Содержание AXIOM 25-49-61
Страница 1: ...Axiom 25 49 61 User Guide Advanced Semi Weighted USB MIDI Controller...
Страница 3: ......
Страница 5: ......
Страница 29: ......
Страница 45: ...051020_Axiom_UG 01...