setting mode
– signalled with (d.br) notice.
In this mode, by means of “+” and “-“ buttons the user has the possibility to set the brightness of the display
segments. Exit from the mode and confirming the setting occurs when the “ON/OFF” button is pressed
shortly. Longer pressing and holding of the button and subsequent releasing of the button will activate the
calibration mode, signalled by the (CAL) notice. In this mode by means of “+” and “-“ buttons, the user has a
possibility to adjust the temperature readings to the real temperature. Exist from the mode and confirming
the calibration settings occurs when the “ON/OFF” button is pressed shortly.
NOTE
– the controllers supplied have been calibrated already.
Longer pressing and holding of the button and subsequent its releasing shall activate the preliminary heating
time setting mode, signalled by (P.tl) notice. In this mode by means of “+” and “-“ buttons the user has a
possibility to define the time after which the controller gets switched from preliminary heating phase to
proper heating phase. Deactivation of preliminary heating is signalled by the “OFF” notice. Exist from the
mode and setting confirmation occurs when the “ON/OFF” button is pressed shortly.
Longer pressing and holding of the button and its subsequent releasing will activate the preliminary heating
temperature setting mode, signalled by (P.tE.) notice. In this mode by means of “+” and “-“ buttons the user
has a possibility to define the preset temperature that shall be maintained during preliminary heating. Exit
from the mode and setting conformation occurs when the “ON/OFF” button is pressed shortly. Longer
pressing and holding of the button and its subsequent releasing will activate the preset temperature limit
setting mode, signalled by (L.t.h.)
notice. In this mode by means of “+” and “-“ buttons the user has the
possibility to set the upper limit of the preset temperature settings. Exit from the mode and setting
confirmation occurs after the “ON/OFF” button is pressed shortly
NOTE – all controller settings and working state (activated or deactivated) are stored in the
non-volatile memory.
Entering the access codes
During controller start-
up (displayed controller’s name, software version, settings), press and hold the “+” and
“-“ buttons. Once “---“ has been displayed on the screen, buttons may be released and the relevant code
can be set. The code shall be confirmed by the “ON/OFF” button.
CODE
ACCESS LEVEL
Any
L-0
157
L-1
314
L-2
628
L-3
942
L-4
Working time setting mode (code L-0)
Display brightness setting mode (code L-0)
Calibration mode (code L-1)
Preliminary heating time setting mode (code L-2)
Preliminary heating temperature setting mode (code L-3)
Preset temperature limit setting mode (code L-4)
Controller error report
HC1 controller has been equipped with advanced mechanisms for error detection. Detection of any
error activates emergency work stoppage and triggers error report screen. Error report screen is displayed
in a continuous manner. It is therefore necessary to disconnect power supply, remove the error source and
controller reconnection
ERROR
ERROR DESCRIPTION
(E-0) CPU
STATUS
Damaging the main processing unit.